Intel RMS25PB080N ユーザーズマニュアル

ページ / 58
28
Intel® Integrated RAID Module RMS25PB080N and RMS25CB080N Hardware User’s Guide
Array Performance Features
Table 7. Array Performance Features
Physical and virtual drive support
128 physical drives, 64 virtual drives, and 32 
RAID arrays per controller
Cache
1 GB DDR3 1333 MHz SDRAM
Firmware
16 MB in reflashable flash ROM
Compatible devices
2.5-inch and 3.5-inch SAS 2.0 or 
SATA III
Non disk devices including expanders
Can support drives of mixed capacity
Cabling
Small, thin cables that do not restrict 
airflow
Shared connectors for multiple drives
Redundant configuration
128 KB NVRAM and config-on-disk (COD)
Enclosure management
SGPIO
Enclosure support
Assumes one SEP per enclosure
Specification
Intel
®
 Integrated RAID Module 
RMS25PB080N and RMS25CB080N
Specification
Intel
®
 Integrated RAID Module RMS25PB080N and 
RMS25CB080N
Host data transfer rate
Up to 8.0 Gigatransfer/sec per PCI Express* lane
Drive data transfer rate
Up to 6.0 Gigabit/sec per PHY
Maximum scatter/gather
80 elements
Maximum size of I/O requests
6.4 Mbytes in 64 Kbyte stripes
Maximum queue tags per 
drive
As many as the drive can accept
Stripe sizes
8, 16, 32, 64, 128, 256, 512, or 1024 KB 
Maximum concurrent 
commands
255
Support for multiple initiators
Yes 
Performance
Native command queuing