Opticis M1-1POE-30 ユーザーズマニュアル
M1-1P0E (Ver. 1.2)
Copyright © 2012, All rights reserved, Opticis Co., Ltd.
Aug. 03, 2012
- 3 -
www.opticis.com
Absolute Maximum Ratings
Parameter
Symbol
Minimum
Maximum
Units
Storage Temperature
T
stg
- 30
+ 70
C
Supply Voltage
V
CC
- 0.3
+ 6.0
V
Transmitter Differential Input Voltage
V
d
-
1
V
Relative Humidity
RH
0
85
%
Lead Soldering Temperature & Time
-
-
260
C, 10 sec
Recommended Operating Conditions
Parameter
Symbol
Minimum
Typical
Maximum
Units
Ambient Operating Temperature
T
A
0
+ 50
C
Data Output Load
R
LD
50
Ω
Power Supply Rejection
(Note1)
PSR
50
mV
p-p
Supply Voltage
V
CC
+ 4.5
+ 5.0
+ 5.5
V
Graphic Supply Voltage
(Note2)
GV
CC
+ 3.0
+ 3.3
+ 3.6
V
Note1.
Tested with a 50mV
p-p
sinusoidal signal in the frequency range from 500 Hz to 500 MHz on the V
CC
supply with
the recommended power supply filter in place. Typically less than a 0.25 dB change in sensitivity is experienced.
Note2. Graphic Supply Voltage is only for the Graphic Signal Interface which is generated by regulator in the Transmitter
and Receiver
Note2. Graphic Supply Voltage is only for the Graphic Signal Interface which is generated by regulator in the Transmitter
and Receiver
Electrical Power Supply Characteristics
1.
For M1-1P0E with the external power adaptor, the characteristics are as follows;
Parameter
Symbol
Minimum
Typical
Maximum
Units
Supply Voltage
V
CC
4.5
5
5.5
V
Supply Current
TX
I
TCC
-
170
200
mA
RX
I
RCC
-
130
150
mA
Power
Dissipation
Dissipation
TX
P
TX
0.85
1.1
W
RX
P
RX
-
0.65
0.825
W