Opticis M1-1POE-30 ユーザーズマニュアル

ページ / 8
 
M1-1P0E (Ver. 1.2)
 
 
 
Copyright ©  2012, All rights reserved, Opticis Co., Ltd.  
 
Aug. 03, 2012 
 
- 3 - 
www.opticis.com 
 
Absolute Maximum Ratings 
 
Parameter 
Symbol 
Minimum 
Maximum 
Units 
Storage Temperature 
T
stg
 
- 30 
+ 70 
Supply Voltage 
V
CC
 
- 0.3 
+ 6.0 
Transmitter Differential Input Voltage 
V
d
 
Relative Humidity 
RH 
85 
Lead Soldering Temperature & Time 
 
260
C, 10 sec 
 
 
 
Recommended Operating Conditions 
 
Parameter 
Symbol 
Minimum 
Typical 
Maximum 
Units 
Ambient Operating Temperature 
T
A
 
 
+ 50 
Data Output Load 
R
LD
 
 
50 
 
Ω 
Power Supply Rejection 
(Note1)
 
PSR 
 
50 
 
mV
p-p
 
Supply Voltage 
V
CC
 
+ 4.5 
+ 5.0 
+ 5.5 
Graphic Supply Voltage
  (Note2)
 
GV
CC
 
+ 3.0 
+ 3.3 
+ 3.6 
Note1. 
 
Tested with a 50mV
p-p
 
sinusoidal signal in the frequency range from 500 Hz to 500 MHz on the V
CC
 
supply with  
             the recommended power supply filter in place. Typically less than a 0.25 dB change in sensitivity is experienced. 
 
Note2.  Graphic Supply Voltage is only for the Graphic Signal Interface which is generated by regulator in the Transmitter 
             and Receiver 
 
 
 
 
Electrical Power Supply Characteristics
 
 
 
1. 
For M1-1P0E with the external power adaptor, the characteristics are as follows; 
 
 
Parameter 
Symbol 
Minimum 
Typical 
Maximum 
Units 
Supply Voltage 
V
CC
 
4.5 
5.5 
Supply Current 
TX 
I
TCC
 
170 
200 
mA 
RX 
I
RCC
 
130 
150 
mA 
Power 
Dissipation 
TX 
P
TX
 
 
0.85 
1.1 
RX 
P
RX
 
0.65 
0.825