Monessen Hearth Series ユーザーズマニュアル

ページ / 20
18 
71D0530
MODEL AK-4 COMBUSTION AIR ASSEMBLY 
(CONTINUED)
 
7.  If the duct is the insulated type, push the insulation back from one end of 
the duct approximately 2". See Figure 23.
8.  Slip the exposed end of the duct over the starting collar on the fi replace.
9.  Using the sheet metal screws provided, secure the duct end to the collar 
attached to the fi replace.
10.  Nail or screw the combustion air assembly to the surface of the wall.
Note: If the wall covering is brick or stone, use appropriate 
masonry fasteners. If necessary, splice the duct. Use a model 
403-duct connector to splice duct sections.
INSTALLING MODEL 403 DUCT CONNECTOR
1.  Push insulation back approximately 2" from the end of each duct.
2.  Slip each duct over duct connector until an equal length of connector extends into each duct.
3.  Place duck clamp over the end of each duct. Tighten duct clamp down snuggly. 
4.  Push insulation back into place and over duct clamp.
Figure 23 - Installing Duct 
Connector 403
Approximately
2"
Insulation
Duct 
Connector 
Duct Clamp 
FOR USE OF OPTIONAL AK-4 OUTSIDE AIR KIT