Toshiba Strata DK Admin ユーザーズマニュアル

ページ / 178
Upgrading to RCTUE/F
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
146
DKAdmin/DKBackup
5. Using the Backup/Restore Data function on the Administration Menu, download the 
complete customer database via modem or disk by pressing 
F2
 then 
F3
.
After the customer database is downloaded and built, it can be upgraded to the RCTUE/F 
processor.
6. Install the RCTUE/F processor into the DK280 or DK424 base cabinet (see the Strata 
I&M Manual for more details). Remove the MBJU (DK424 Base only).
7. From the programming telephone, run Program 91-9 twice to initialize the RCTUE/F 
processor. 
8. From the programming telephone run Programs 03, 76, and 77-1 to set up the TTY 
interface port.
9. Turn the system power off for five seconds then turn the power back on.
10. Connect the DKAdmin PC to the system TTY interface port; check communication 
between the DKAdmin program and RCTUE/F processor is operating properly.
11. Using DKAdmin, select the customer database created in 
Step 2
.
12. Check the PCB code for the TTY PCB (PIOU, RSIU, etc.) is set properly in Program 03.
13. From the Administration Menu, select the Back/Restore Data function and press 
Enter. 
Press 
F5
 to select Upgrade.
14. Follow the upgrade steps in DKAdmin; select the RCTUE/F processor. Answer 
No
 to 
“Backup From DK First?” and 
No
 to “Pull Program 03?”.
15. After DKAdmin upgrades and uploads the customer database, it prompts you to “Perform 
Automatic Power OFF/ON”; answer 
Yes
. DKAdmin runs Program 91-2, then prompts 
you to receive data to complete the upgrade process; answer 
Yes
. DKAdmin downloads 
the upgraded RCTUE/F database and builds the customer file.
16. The upgrade is now complete. Install the upgraded RCTUE/F at your customer site.
On-Site Upgrade
 If upgrading on-site, the DKAdmin upgrade process pulls the current existing customer 
database.
To do an on-site upgrade
1. Connect the DKAdmin PC to the system TTY interface port; check that DKAdmin is 
communicating with the existing RCTU processor.
2. From the File Menu, type 
m
 to select the Maintain Customer File function.
3. Create a new customer database by selecting the existing DK16e or RCTU (A, B, BA/BB, 
or C/D) and Release (Release 1/Release 2 or Release 3 version).
4. Select the new customer created in 
Step 3
5. From the Administration Menu, select the Back/Restore Data function and press 
Enter. 
Press 
F5
 to select Upgrade.
6. Follow the upgrade steps in DKAdmin; select the RCTUE/F processor. Answer 
Yes
 to 
“Backup From DK First?” and 
Yes
 to “Pull Program 03?”. DKAdmin downloads the 
database from the existing RCTU processor. 
7. After DKAdmin downloads the database from the existing RCTU processor, DKAdmin 
prompts you to change the processors etc. (i.e., turn power off, remove the existing 
Get user manuals: 