Toto TEU2ANS-21 ユーザーズマニュアル

ページ / 2
Step 3
Join one lead wire, one supplied wire to flush valve and
one wire for another junction box using a wire nut.  Join
the other sets of wires using another wire nut.
Fasten the connection wire to the cover of the junction
box.
To junction box
Wire nut
Supplied 
connection wire
Fasten the connection wire
To flush valve 
sensor
For AC Type
Step 4
Fasten the box to the box fixing frame with four screws (To
be prepare on the site) after adjusting it. ( A )
Secure the box with four screws attached to adjustable
plate. ( B )
Fasten the connection wire at the position of the mark
colored red with the clamp. ( C )
Adjustable
plate
Clamp
Adjustable hole
A
C
B
Box
Step 5
Pass the flush pipe and the vacuum breaker through the
hole bored in Step 1 and then mount them on the bowl.
Wall surface
Bowl
Top spud
1-1/2"
6    6-1/2"
(152   165mm)
3-3/4"
(95mm)
2-1/4"    2-3/4"
(57    70mm)
5"
(127mm)
Wall surface
Back spud
Wall mount
Bowl
3-3/4"
(95mm)
1-1/2"
3"
(76mm)
Step 6
Make sure that the O-ring fits in the groove of the
connecting pipe.
O-ring
Snap ring
Step 7
Insert the end of the stainless cable for manual flushing
into the hinge hole. ( A )
Slide the cable casing into the opening of the bracket. ( B )
Make sure the rod of the flush valve is thrusted when the
button is pushed.
For Toilet flush valve
Before installing the cable, the bracket should be
reinstalled to the opposit direction.
( C , and also see Step 1)
For the left water supply
Test Run
1. Energize the primary side of the transformer (THU701TR
or THU700TR)   For AC Type 
2. Make sure the control stop is open.
3. Sit on the toilet seat. (for Toilet flush valve)
Stand within two feet from the front of the flush valve.
(for Urinal flush valve)
4. Stay there for six seconds or more and leave the toilet
seat or the urinal. The valve will automatically flush.
5. Press the manual flushing button and make sure the
valve flushes properly. (for Toilet flush valve)
6. Recheck all the pipe connections for water leaks.  If the
flush valve is not operating properly following the test
run consult the Troubleshooting section of the Owner’s
Manual. Recheck installation procedures only after
turning off and locking out breaker for power line
Note to the installer
After the flush valve unit has been installed correctly,
please explain to your customer how to use it and tell him
or her to observe the following instructions.
1. Do not put any object in front of the sensor window
which could obstruct the sensor, causing the flush valve
to malfunction.
2. For troubleshooting, consult the Owner’s Manual.
1
To minimize the risk of electrical shock and fire
hazard, turn off and lock out breaker for power line
before attempting troubleshooting, maintenance,
adjustment or repairs.
2
If you lack the necessary skills required or have
difficulty following the directions for installation,
maintenance, repairs, troubleshooting or
adjustments, of the product, do not proceed without
help from a qualified person to assist you in
performing any of these functions.
Adjustment
WARNING:  To minimize the risk of electrical shock and
fire hazard, turn off and lock out breaker for
power line before starting adjustment.
1. Adjustment of the discharge quantity
(1) Remove the front cover.
(2) Adjust the discharge quantity by rotating the screw
on the piston valve.
Wiring
WARNING:  To minimize the risk of electrical shock and
fire hazard, turn off and lock out breaker for
power line before starting wiring.
This product must be connected to the type of power
source indicated on the installation instruction. If you are
not sure of the type of power source available, consult
your dealer or local power company.
The wiring diagram is shown below.
When connecting the secondary side of the transformer
to each flush valve, use only UL Class 
ΙΙ
No.18 wires.
- Wiring Diagram -
Installation of the Transformer
WARNING: Whenever installing the transformer or wiring,
turn off and lock out breaker for power line in
order to minimize the risk of electrical shock or
fire hazard.
2. Adjustment of the flow rate
Adjust the flow rate by turning the screw/handle of the
control stop.
Turn the screw/handle to the right to decrease the flow
rate and turn it to the left to increase.
3. Adjustment of the detection range
The detection range of the infrared sensor does not
need to be adjusted because it has been factory-preset.
This automatic flush valve unit requires a special
transformer. When installing the transformer, please
observe the following instruction.
1. The wiring distance from the transformer to the flush
valve must be 45 feet (13.5m) or less. 
Use UL class 
ΙΙ
No.18 wire when connecting the flush
valve to the transformer.
2. This transformer can be connected to a maximum of 10
flush valves.
WARNING: Be sure to ground the 4"SQ box to eliminate
the risk of electrical shock or fire hazard.
Never kink or bend primary-side lead wires
and/or secondary-side lead wires of the
transformer when wiring them in the conduit
tube or the junction box altogether.
To increase
To decrease
4"SQ-2-1/4"DEEP
Primary-side lead wires
(120V or 24V AC)
Secondary-side lead wires
(10V DC,1.95A)
Condult tube
(CONDUCTKO’S)
Transformer
V1
V2
V1
V2
Unit #1
Solenoid valve
6VDC
Unit #2
Solenoid valve
6VDC
Junction  box
Junction  box
Two·pole beraker
Transformer
120VAC60Hz, to 10VDC(THU701TR)
1.95A
or
24VAC60Hz,to 10VDC(THU700TR)
1.95A 
A maximum of ten units
can be connected.
Sensor
Sensor
For TET2ANS-32
TET2DNS-32
For TET2ANS-31
TET2DNS-31
Wall surface
Back spud
Floor mount
Bowl
3-3/4"
(95mm)
1-1/2"
Wall surface
3-3/4"
(95mm)
3/4"or 1-1/4"
For TET2ANS-33
TET2DNS-33
For TEU2ANS-11,21
TEU2DNS-11,21
Original
for the right water supply
for the left water supply
Cable casing
Stainless cable
Cable casing
Hinge
Bracket
Bracket
Hinge
A
B
C
Step 8
Tighten the coupling nut to prevent a water leak.
Coupling nut
Coupling nut
Step 11
For AC Type
Remove the battery case from the box.
Install the supplied 4 batteries into the battery case. Install
the battery case with the 4 batteries into the box exactly as
shown in the figure.
Connect the infrared sensor with the battery case by using
the connection wire.( A , B )
Connect the infrared sensor with the solenoid by using the
connection wire.( C , D )
For DC Type
A
C
B
B
A
C
D
Battery
Battery case
Screw (Not used)
Step 12
Control stop
Open
Step 13
Fasten the front cover to the box by tightening the screws
with the supplied tool. (Allen wrench)
Take care so that any cord, wire or chain might not be
caught between the front cover and the box.
Manual flush button
(Only for toilet flush valve)
Allen wrench
For only AC Type
Step 10
Connect the chain from the front cover with a hole on the
Hole
Open the control stop.
Do not proceed to step 13 until all water leaks are
eliminated by tightening all the pipe connections. Failure to
correct all water leaks prior to use may increase the risk of
electrical shock, fire hazard or damage to the product.
Connect the flush valve with the control stop and the
vacuum breaker.
Step 9
Attach the connector of the infrared sensor unit with the
connector from the junction box. ( A )
Attach the connector of the infrared sensor unit with the
connector from the solenoid by using connection wire. 
( B , C )
Printed in August, 2001