Toshiba VF-AS1 ユーザーズマニュアル

ページ / 326
  E6581301 
F-3 
6.2 
Input signal selection 
6.2.1  Priority  when  forward/reverse  run  commands  are  entered  simultaneously!!!!
H
H
H
H    : Priority when forward/reverse run commands are entered 
simultaneously 
• Function  
This parameter allows you to select the direction in which the motor runs when a forward run (F) command 
and a reverse run (R) command are entered simultaneously.  
1) Reverse run 
2) Deceleration stop 
[Parameter setting] 
Title 
Function 
Adjustment range 
Default setting 
H
Priority when forward/reverse run 
commands are entered 
simultaneously 
:Reverse run, :Stop 
Output  frequency  [Hz] 
  Forward  run 
  Reverse  run 
Forward  run  signal
Reverse  run  signal
ON 
OFF
ON 
OFF
If a F command and a R command are entered simultaneously, 
the motor will run in the reverse direction.
0
Set  frequency
Set  frequency
Time  [s] 
[H=(Reverse  run)]   
!
Forward  run  signal
Reverse  run  signal
Output  frequency  [Hz]!
Set  frequency
  Forward  run  !
  Reverse  run  !
ON!
OFF!
ON!
OFF!
If a F command and a R command are entered simultaneously 
the motor will slow down to a stop.
!
Time  [s]  !
0
[H=  (Stop)]  !
!