Toshiba VF-AS1 ユーザーズマニュアル

ページ / 326
!
K
-1
!
!
E
6
5
8
1
3
0
1
11
 
11. Table of parameters
1. User parameter 
*3 Sensorless vector/vector with sensor (
Ɣ:Effective, -:Ineffective) 
Title 
Communi
cation 
No. 
Function 
Adjustment range 
Minimum 
setting unit 
(Panel/Communi
cation)
Default 
setting
Write during 
running 
Vector control
PM 
control
*2 
V/f 
*1 
Reference
Speed 
control
Torque 
control
HE
Operation frequency of
operation panel
NN~HJ Hz 
0.1/0.01 
Enabled
Ɣ/Ɣ
Ɣ/Ɣ
Ɣ
Ɣ 
3. 2 
*1: V/f : Any setting of RV=,,*2: PM control : RV= setting    *3: Sensorless vector : Any setting of RV=,, / Vector with sensor : Any setting of RV=,
2. Basic parameter [1/4] 
  Sensorless vector/vector with sensor (
Ɣ:Effective, -:Ineffective) 
Title 
Communi
cation 
No. 
Function 
Adjustment range 
Minimum 
setting unit 
(Panel/Communi
cation)
Default 
setting
Write during 
running 
Vector control
PM 
control
V/f 
Reference
Speed 
control
Torque 
control
CWJ
-
History function
1/1
-
-
Ɣ/Ɣ
Ɣ/Ɣ
Ɣ
Ɣ
5. 1
CW
0000 
Automatic 
acceleration/deceleration
0:Disabled
1:Automatic setting 
2:Automatic setting (during acceleration only) 
1/1 
Disabled
Ɣ/Ɣ 
Ɣ
Ɣ 
5. 2 
CW
0001 
Automatic torque boost 
0:Disabled
1:Automatic torque boost + auto-tuning 1 
2:Sensorless vector control 1+ auto-tuning 1
1/1 
Disabled
Ɣ/Ɣ 
Ɣ
Ɣ 
5. 3 
CW
0040 
Automatic function 
setting 
0:Disabled
1:Frequency setting by means of voltage 
2:Frequency setting by means of current 
3:Voltage/current switching from external terminal 
4: Frequency setting on operation panel and operation by 
means of terminals 
5: Frequency setting and operation on operation panel 
1/1 
Disabled
Ɣ/Ɣ
Ɣ/Ɣ
Ɣ
Ɣ 
5. 4 
EOQF
0003 
Command mode 
selection 
0:Terminal input enabled
1:Operation panel input enabled (including LED/LCD 
option input) 
2:2-wire RS485 communication input 
3:4-wireRS485 communication input 
4:Communication option input 
1/1 
Disabled
Ɣ/Ɣ
Ɣ/Ɣ
Ɣ
Ɣ 
5. 5 
HOQF
0004 
Frequency setting mode 
selection 1 
1:VI/II (voltage/current input)
2:RR/S4 (potentiometer/voltage input) 
3:RX (voltage input) 
4:Operation panel input enabled (including LED/LCD 
option input) 
5:2-wire RS485 communication input 
6:4-wire RS485 communication input 
7:Communication option input 
8:Optional AI1 (differential current input) 
9:Optional AI2 (voltage/current input) 
10:Motor operated pot mop setting 
11:Optional RP pulse input 
12:Optional high-speed pulse input 
13:- (Unsupported option)
1/1 
Disabled
Ɣ/Ɣ 
Ɣ
Ɣ 
5. 5