Toshiba VF-AS1 ユーザーズマニュアル
!
K
-4
5
E
6
5
8
1
3
0
1
!
11
[Output terminal function setting (1/3)]
Sensorless vector/vector with sensor (Ɣ: valid, -: invalid)
Positive
logic
Negative
logic
Function
Speed control
Torque control
PM control
V/f
Reference
0
1
LL
Ɣ/Ɣ
Ɣ/Ɣ
Ɣ
Ɣ
7.2.2
2
3
UL
Ɣ/Ɣ
Ɣ/Ɣ
Ɣ
Ɣ
4
5
LOW
Ɣ/Ɣ
Ɣ/Ɣ
Ɣ
Ɣ
6
7
Acceleration/deceleration completion
Ɣ/Ɣ
-
Ɣ
Ɣ
8
9
Specified speed arrival
Ɣ/Ɣ
Ɣ/Ɣ
Ɣ
Ɣ
10
11
Failure FL (all trip)
Ɣ/Ɣ
Ɣ/Ɣ
Ɣ
Ɣ
12
13
Failure FL (except for EF, OCL, EPHO and OL2)
Ɣ/Ɣ
Ɣ/Ɣ
Ɣ
Ɣ
14
15
Overcurrent pre-alarm
Ɣ/Ɣ
Ɣ/Ɣ
Ɣ
Ɣ
16
17
Inverter overload pre-alarm
Ɣ/Ɣ
Ɣ/Ɣ
Ɣ
Ɣ
18
19
Motor overload pre-alarm
Ɣ/Ɣ
Ɣ/Ɣ
Ɣ
Ɣ
20
21
Overheat pre-alarm
Ɣ/Ɣ
Ɣ/Ɣ
Ɣ
Ɣ
22
23
Overvoltage pre-alarm
Ɣ/Ɣ
Ɣ/Ɣ
Ɣ
Ɣ
24
25
Main circuit undervoltage alarm
Ɣ/Ɣ
Ɣ/Ɣ
Ɣ
Ɣ
26
27
Low current alarm
Ɣ/Ɣ
Ɣ/Ɣ
Ɣ
Ɣ
28
29
Overtorque alarm
Ɣ/Ɣ
Ɣ/Ɣ
Ɣ
Ɣ
30
31
Braking resistor overload pre-alarm
Ɣ/Ɣ
Ɣ/Ɣ
Ɣ
Ɣ
32
33
In emergency stop
Ɣ/Ɣ
Ɣ/Ɣ
Ɣ
Ɣ
34
35
In course of retry
Ɣ/Ɣ
Ɣ/Ɣ
Ɣ
Ɣ
36
37
Pattern operation switching output
Ɣ/Ɣ
-
Ɣ
Ɣ
38
39
PID deviation limit
Ɣ/Ɣ
-
Ɣ
Ɣ
40
41
Run/Stop
Ɣ/Ɣ
Ɣ/Ɣ
Ɣ
Ɣ
42
43
Serious failure (OCA, OCL, EF, phase failure, etc.)
Ɣ/Ɣ
Ɣ/Ɣ
Ɣ
Ɣ
44
45
Light failure (OL, OC1, 2, 3, OP)
Ɣ/Ɣ
Ɣ/Ɣ
Ɣ
Ɣ
46
47
Commercial/INV switching output 1 (for inverter
operation output)
operation output)
Ɣ/Ɣ
-
Ɣ
Ɣ
48
49
Commercial/INV switching output 2 (for commercial
operation output)
operation output)
Ɣ/Ɣ
-
Ɣ
Ɣ
50
51
Cooling fan ON/OFF
Ɣ/Ɣ
Ɣ/Ɣ
Ɣ
Ɣ
52
53
In Jog run
Ɣ/Ɣ
-
Ɣ
Ɣ
54
55
Panel operation/terminal board operation switching
Ɣ/Ɣ
Ɣ/Ɣ
Ɣ
Ɣ
56
57
Cumulative operation time alarm
Ɣ/Ɣ
Ɣ/Ɣ
Ɣ
Ɣ
58
59
PROFIBUS/DeviceNet/CC-Link communication error
Ɣ/Ɣ
Ɣ/Ɣ
Ɣ
Ɣ
60
61
Forward/reverse run
Ɣ/Ɣ
Ɣ/Ɣ
Ɣ
Ɣ
62
63
Ready for operation 1
Ɣ/Ɣ
Ɣ/Ɣ
Ɣ
Ɣ
64
65
Ready for operation 2
Ɣ/Ɣ
Ɣ/Ɣ
Ɣ
Ɣ
68
69
Braking release signal
Ɣ/Ɣ
-
Ɣ
Ɣ
70
71
In (pre-)alarm status
Ɣ/Ɣ
Ɣ/Ɣ
Ɣ
Ɣ
72
73
Forward speed limit (torque control)
-
Ɣ/Ɣ
-
-
74
75
Reverse speed limit (torque control)
-
Ɣ/Ɣ
-
-