Toshiba VF-AS1 ユーザーズマニュアル

ページ / 326
!
  E6581301 
L-1 
12 
12. Specifications 
12.1 
Models and their standard specifications 
1) Standard specifications (small/medium capacity types)   
Item 
Specification 
Voltage class 
200V class 
Applicable motor (kW)   
0.4
0.75
1.5
2.2
3.7/4.0
5.5
7.5 
11 
15 
18.5
22 
30 
37 
45 
Applicable motor (HP)   
0.5
7.5
10 
15 
20 
25 
30 
40 
50 
60 
R
a
tin
g
 
Type 
VFAS1- 
Form 
2004PL 2007PL 2015PL 2022PL 2037PL 2055PL 2075PL 2110PM 2150PM 2185PM 2220PM 2300PM 2370PM 2450PM
Output capacity (kVA) 
[Note 1]
1.1
1.8
3.0 
4.2 
6.7 
10 
13 
21 
25 
29 
34 
46 
55 
67 
Output current
(A)    [Note 2] 
3.0 
(3.0)
4.8 
(4.5) 
8.0
(8.0)
11 
(10.5)
17.5 
(16.6) 
27.5 
(25.0)
33 
(33)
54 
(49)
66 
(64) 
75 
(66)
88 
(75)
120
(88)
144
(120)
176
(140)
Output voltage
Three-phase 200V~240V (The maximum output voltage is equal to the input supply voltage.)   
Overload 
current rating 
150%-1 minute, 165%-2 sec. 
El
e
c
tr
ic
a
b
ra
k
in
g
 
Dynamic 
braking circuit 
Built-in dynamic braking drive circuit   
Dynamic braking 
resistor 
An external braking resistor (optional)   
!
Ÿ
 Rating: Refer to 5.19.   
Po
w
e
s
u
p
p
ly
Voltage-frequency
! ! ! ! ! ! ! ! ! Three-phase 200~240V-50/60Hz    [Note 3] 
Allowable 
fluctuation 
Voltage + 10% - 15%    [Note 4]        Frequency ±5% 
Protective method 
(IEC60529)   
IP20 Enclosed type 
IP00 Open type      [Note 5]
Cooling method 
Forced air-cooled 
Cooling fan noise (dBA)
43 
43 
43 
55 
55 
56 
58 
60 
60 
60 
60 
64 
64 
64 
Color 
RAL7016 
EMC filter 
Built-in 
Basic filter (Not complies with the European EMC Directive) 
DC reactor 
External DC reactor (option) 
Built-in 
Item 
Specification 
Voltage class 
400V class 
Applicable motor (kW)   
0.75
1.5
2.2
3.7/4.0
5.5
7.5
11 
15 
18.5
22 
30 
37 
45 
55 
75
Applicable motor (HP)   
7.5
10 
15 
20 
25 
30 
40 
50 
60 
75 
100
R
a
tin
g
 
Type 
VFAS1- 
Form 
4007PL 4015PL 4022PL 4037PL 4055PL 4075PL 4110PL 4150PL 4185PL 4220PL 4300PL 4370PL 4450PL 4550PL 4750PL
Output capacity (kVA) 
[Note 1]
1.8 
3.1 
4.4 
8.0
11 
13 
21 
25 
31 
37 
50 
60 
72 
88 
122
Output current 
(A)    [Note 2] 
2.3 
(2.3) 
4.1
(4.0) 
5.8
(4.6) 
10.5
  (8.6)
14.3 
(13)
17.6 
(17)
27.7 
(25)
33 
(32)
41 
(37)
48 
(38)
66 
(53)
79 
(60)
94 
(75)
116
(93)
160
(120)
Output voltage
Three-phase 380V~480V (The maximum output voltage is equal to the input supply voltage.)   
Overload 
current rating 
150%-1 minute, 165%-2 sec. 
El
e
c
tr
ic
a
b
ra
k
in
g
 
Dynamic 
braking circuit 
Built-in dynamic braking drive circuit   
Dynamic braking 
resistor 
An external braking resistor (optional)   
!
Ÿ
 Rating: Refer to 5.19. 
Po
w
e
s
u
p
p
ly
Voltage-frequenc
! ! ! ! ! ! ! ! ! ! ! ! ! ! ! Three-phase 380~480V-50/60Hz    [Note 3]
Allowable 
fluctuation 
Voltage + 10% - 15%    [Note 4]        Frequency ±5% 
Protective method
(IEC60529)
IP20 Enclosed type 
IP00 Open type    [Note 5]
Cooling method
Forced air-cooled 
Cooling fan noise (dBA)
43 
43 
43 
55 
56 
56 
58 
60 
60 
60 
64 
64 
64 
64 
64 
Color
RAL7016 
EMC filter
Built-in 
DC reactor
External DC reactor (option) 
Built-in 
Note 1: Capacity is calculated at 220V for the 200V models and at 440V for the 400V models. 
Note 2: Rated output current when the PWM carrier frequency (parameter EH) is 4kHz or less.   
The values between parentheses refer to rated output currents when set to 12kHz.   
Ÿ
 Refer to 1.4.4 ”Current reduction curve” for details.   
Note 3: If you are using a 200V-15kW or 400V-2.2kW inverter and the ambient temperature is 40°C or mor e, 
decrease the PWM carrier frequency to 8kHz. Setting H to  enables you to protect the overload 
caused by ambient temperature described in page A-23. 
An external power supply backup available (optional) (Type: CPS002Z)   
Note 4: ±10% when the inverter is used continuously (load of 100%).
   
Note 5: HN models, 200V-18.5!45kW and 400V-22!75kW are IP20 enclosed type.