Toshiba VF-AS1 ユーザーズマニュアル

ページ / 326
  E6581301 
E-2 
5
5.2 
Setting acceleration/deceleration time 
 CW
CW
CW
CW
  : Automatic acceleration/deceleration 
 CEE
CEE
CEE
CEE
  : Acceleration time 1 
 FGE
FGE
FGE
FGE
  : Deceleration time 1 
5.2.1  Automatic  acceleration/deceleration
This automatically adjusts acceleration and deceleration time in line with load size.   
CW
CW
CW
CW    =
* Adjusts the acceleration/deceleration time automatically within the range of 1/8 to 8 times as long as the 
time set with the CEE
CEE
CEE
CEE or FGE
FGE
FGE
FGE, depending on the current rating of the inverter. 
CW
CW
CW
CW    =
* Automatically adjusts speed during acceleration only. During deceleration, speed is not adjusted 
automatically but reduced at the rate set with FGE
FGE
FGE
FGE. 
Deceleration 
Acceleration 
HJ
HJ
HJ
HJ
When load is small 
Time [s]
0
Deceleration 
Acceleration 
HJ
HJ
HJ
HJ
When load is large 
Output     
frequency [Hz] 
Output   
frequency [Hz] 
Time [s]
0
Acceleration/deceleration time 
 decrease
Acceleration/deceleration time 
 increase
  Set CW
CW
CW
CW (automatic acceleration/deceleration) to 
 or 
[Parameter setting]
Title 
Function 
Adjustment range 
Default setting 
CW
Automatic acceleration/deceleration
:Disabled (Manual setting) 
:Automatic setting 
:Automatic setting (during 
acceleration only) 
!
When automatically setting acceleration/deceleration time, always change the acceleration/deceleration time so 
that it conforms with the load. 
The acceleration/deceleration time changes constantly with load fluctuations. 
For inverters that requires a fixed acceleration/deceleration time, use the manual settings (CEE, FGE).   
!
When using a braking resistor or braking unit, do not set the CW=. Or the regenerative braking resistor may be 
overloaded. 
!
Use this parameter after actually connecting the motor.   
!
Setting acceleration/deceleration time (CEE, FGE) in conformance with mean load allows optimum setting that 
conforms to further changes in load.   
!
When the inverter is used with a load that fluctuates considerably, it may fail to adjust the acceleration or 
deceleration time in time, and therefore may be tripped.   
• Function 
1)  For acceleration time 1 CEE programs the time that it takes for the inverter output frequency to go from 
0Hz to maximum frequency HJ.   
2)  For deceleration time 1 FGE programs the time that it takes for the inverter output frequency to got from 
maximum frequency HJ to 0Hz.