Quick Installation
1
  Plug the UPS into an outlet.
NOTE! after you plug the UPS into a live AC 
outlet, the UPS will turn ON automatically. 
See “ON/OFF” Button description in the 
Basic Operation section if you want to 
place the UPS in any mode other than ON.
Note: UPS system will function properly upon initial 
startup; however, maximum runtime for the unit’s 
battery will only be accessible after it has been charged 
for 24 hours.
2
  Plug your equipment into the 
UPS.
The 
A
 outlets will provide battery backup 
and surge protection; plug your computer, 
monitor and other critical devices here.* The 
B
 outlets will provide surge protection only; 
plug your printer and other non-essential 
devices here.
* Your UPS is designed to only support computer 
equipment. You will overload the UPS if the total VA 
ratings for all the equipment you connect to the (A) 
outlets exceeds the UPS’s Output Capacity (see 
Specifications). To find your equipment’s VA ratings, 
look on their nameplates. If the equipment is listed in 
amps, multiply the number of amps by 120 to determine 
VA. (Example: 1 amp × 120 = 120 VA). If you are 
unsure if you have overloaded the (A) outlets, run a 
self-test (see “MUTE/TEST” Button description). 