Wiring Connections 
 
Wiring Connections
 
 
2.
  Make Phone Line Connections - For local or full line 
seizure proceed to the appropriate steps below. 
Local Seizure 
a. Connect the incoming phone line to either the 
8-position jack or terminals 2 (TIP) and 3 (RING) on 
the Lynx. 
b.  Connect the handset phone lines to either the RJ11 
jack or terminals 4 (TIP) and 5 (RING). 
Full Line Seizure: The control must be placed in 
series with the incoming phone line. Plugging the 
Direct Connect Cord directly into the RJ31X jack, allows 
the control to seize the phone line when an alarm 
occurs and normal phone line usage by the premises 
phones if the plug needs to be removed. 
a. Cut the incoming RING and TIP phone lines 
(typically red and green, respectively) and connect 
them to RJ31X terminals 4 (red) and 5 (green). 
b.  Connect the premises end of the cut RING and TIP 
wires to RJ31X terminals 1 (grey) and 8 (brown) 
respectively. 
c.  Wire the flying leads of a Direct Connect Cord to the 
control’s phone terminals as shown in the diagram 
or plug into the 8-position jack.  
d.  Plug the Direct Connect Cord into the RJ31X jack. 
 
RJ31X
1
2
3
4
5
6
7
8
RING
TIP
INCOMING
PHONE LINE
TO
PREMISES PHONES
TIP     RING     TIP    RING
BR
O
W
N
GREY
RED
GREEN
INCOMING
PHONE LINE
TO
PREMISES
PHONES
}
}
GREEN
RED
GREY
BROWN
RING
TIP
DIRECT
CONNECT
CORD
OR
OR
8-POSITION
JACK
01000-008-V0
 
 
Full Line Seizure Connections 
 
 
 
HARDWIRED ZONE:  If the EOLR is not at the end of the loop, the zone will not be properly 
supervised, and the system may not respond to an open circuit on the zone.
 
 
3.
  Make Hardwired Zone Connections - Zone 1 is an EOLR supervised zone that supports both open circuit and closed 
circuit devices and has a response time of 350msec. Maximum zone resistance: 300 ohms, plus EOLR 
Note:  The hardwire zone cannot be used as a fire zone. 
a.  Connect sensors/contacts to the hardwired zone terminals 6 (+) and 7  (–).  Refer to the Summary of Connections 
diagram. 
b.  Connect closed circuit devices in series in the high (+) side of the loop. The EOL resistor must be connected in 
series with the devices, following the last device. 
c.  Connect open circuit devices in parallel across the loop. The 2000-ohm EOLR must be connected across the loop 
at the last device. 
 
4.  Make External Sounder Connections - The control panel supports either a 6-14VDC piezo sounder (30mA max.) or 
6-14VDC bell (120mA max.; e.g. ADEMCO WAVE2EX).  
a.  Connect a piezo sounder to terminals 10 (+) and 11 (–); OR a bell to terminals 11 (–) and 12 (+). 
 
 
LOCAL SOUNDER DISABLE: The Master Keypad’s built-in piezo sounder can be disabled by 
removing the shorting jumper (shunt) on the terminal board. If disabled, however, no sounding 
will occur upon AC loss, since the external sounder does not operate when AC power is lost.
 
 
U
U
U
ULLLL    
 
Do not remove shorting jumper (the shunt) for UL installations. 
 
5.  Disable Local Sounder Option 
- If required the Master Keypad’s built-in piezo sounder can be disabled. 
a.  Remove the shorting jumper (shunt) on the terminal board.  
 
6.  Make Powerline Carrier Device Connections - The control panel supports up to 8 Powerline Carrier Devices. If using 
these devices, they must be connected to the ADEMCO 1332X10 transformer, as shown in the SUMMARY OF 
CONNECTIONS diagram. 
a.  Connect the com/data/sync/ lines from the ADEMCO 1332X10 transformer to terminals 9, 13, and 14, respectively.  
Note:  If not using the supplied Ademco connection cable, you may need to reverse the black and yellow wire connections. Refer to the 
80 Device Programming Menu Mode section for details on programming Powerline Carrier Devices. 