JVC VN-X35U ユーザーズマニュアル

ページ / 111
57
B
FTP
Time Filter:
For specifying the periodic FTP transfer action with respect to each day of 
the week and setting the corresponding time of the day.
Applicable day of week : Sunday, Monday, Tuesday, Wednesday, 
Thursday, Friday, Saturday
Alarm action
Unmask Span
: For specifying the time period for invoking the 
action
Mask Span
: For specifying the time period to stop the action
Unmask All
: Activated at all times
Mask All
: Stopped at all times
Applicable time period : For specifying the start and end time in hours and 
minutes.
Pre-/Post-recording parameter:
[PrePostRecording Frame Rate]
: For specifying the JPEG frame rate for  
FTP pre-/post-recording.
[PrePostRecording Before Trigger] : For setting the FTP pre-recording 
trigger time (recording time before 
alarm input) in seconds.
[Setting range: 0 to 60 seconds]
[PrePostRecording After Trigger]
: For setting the FTP post-recording 
trigger time (recording time after alarm 
input) in seconds.
[Setting range: 0 to 60 seconds]
Memo:
                                                                                      
● The maximum time intervals for [PrePostRecording Before Trigger] and 
[PrePostRecording After Trigger] are determined by the JPEG size on the 
Encoding page as well as the set values for [PrePostRecording Frame 
Rate]. A message appears if the combination of the entered values are 
not feasible.
C
Alarm Output
For setting the alarm output.
Duration
For setting the output time of [Manual Output].
[Setting range: 0, 100 msec to 5000 msec]
Manual 
Output
For operating alarm output manually.
The current output status appears on the right. When [Duration] is set to “0”, 
pressing the [Make] button switches the alarm to Make output, while 
pressing the [Break] button switches the alarm to Break output.
When [Duration] is set to a value other than “0”, pressing the [Make] button 
switches the alarm to Make output only during the duration of the output, 
upon which it switches to Break output.
When the output duration is set to a value other than “0”, pressing the 
[Break] button switches the alarm to Break output only during the duration of 
the output, upon which it switches to Make output.