Juniper ACX1100 ACX1100-AC データシート
製品コード
ACX1100-AC
3
Specifications
This section lists basic specifications for the ACX Series routers. For further details, please refer to the hardware installation manuals on
www.juniper.net/techpubs/hardware.
www.juniper.net/techpubs/hardware.
Specification
ACX1000 and ACX1100
ACX2000 and ACX2100
ACX4000
Dimensions
(W x H x D)
(W x H x D)
17.5 x 1.75 x 9.4 in
(44.5 x 4.4 x 24 cm)
(44.5 x 4.4 x 24 cm)
17.5 x 1.75 x 9.4 in
(44.5 x 4.4 x 24 cm)
(44.5 x 4.4 x 24 cm)
17.5 x 4.35 x 9.25 in
(44.5 x 11 x 23.5 cm)
(44.5 x 11 x 23.5 cm)
Weight (lb/kg) fully configured
6.5 lb (2.94 kg) for ACX1000
7.8 lb (3.54 kg) for ACX1100
7.8 lb (3.54 kg) for ACX1100
8.3 lb (3.77 kg)
23.8 lb (10.82 kg)
(Fully configured with two power
(Fully configured with two power
supply units, two Modular Interface
Controllers (MICs)
Power (DC)
-48 V, -60 V telco nominal or
+24 VDC nominal
-48 V, -60 V telco nominal or
+24 VDC nominal
-48 V, -60 V telco nominal or
+24 VDC nominal
Power (AC)
90 to 240V AC for ACX1100-AC*
only
90 to 240 V AC for ACX2100-AC*
only
90 to 240 V AC
Maximum power draw
50W (ACX1000); 35W (ACX1100-
AC); 40W (ACX1100-DC)
70W (ACX2000); 60W (ACX2100-
AC); 80W (ACX2100-DC)
150W (w/o MICs); 45W for each
MIC; 65W for each PoE++ port
Operating temperature
-40° F to 158° F (-40° C to 70° C)
-40° F to 149° F (-40° C to 65° C)
full featured
-40° F to 158° F (-40° C to 70° C)
Humidity
95% RH noncondensing
95% RH noncondensing
95% RH noncondensing
Noise level
0 dB (acoustic noise) (negligible—
only passive cooling is used)
0 dB (acoustic noise) (negligible—
only passive cooling is used)
33 dBA at 27 degrees C ambient
temperature
*ACX1100-AC and ACX-2100-AC models will start shipping in 2Q2013.
ACX1000
ACX1100DC
ACX2000
ACX2100DC
ACX4000DC
Approvals
Safety Approvals
• CAN/CSA-C22.2 No. 60950-1
• UL 60950-1
• EN 60950-1
• IEC 60950-1 – CB Scheme
• EN 60825-1
• UL 60950-1
• EN 60950-1
• IEC 60950-1 – CB Scheme
• EN 60825-1
EMC
• AS/NZS CISPR22 Class A
• EN55022 Class A
• VCCI Class B
• FCC Part 15 Class A
• EN55022 Class A
• VCCI Class B
• FCC Part 15 Class A
Immunity
• EN-61000-3-2 Power Line Harmonics
• EN-61000-3-3 Voltage Fluctuations and Flicker
• EN-61000-4-2 ESD
• EN-61000-3-3 Voltage Fluctuations and Flicker
• EN-61000-4-2 ESD
• EN-61000-4-3 Radiated Immunity
• EN-61000-4-4 EFT
• EN-61000-4-5 Surge
• EN-61000-4-6 Low Frequency Common Immunity
• EN-61000-4-11 Voltage Dips and Sags
• EN-61000-4-4 EFT
• EN-61000-4-5 Surge
• EN-61000-4-6 Low Frequency Common Immunity
• EN-61000-4-11 Voltage Dips and Sags
ETSI
• ETSI EN300386-2 Telecommunication Network Equipment,
Electromagnetic Compatibility Requirements
• ETSI EN 300 019-2-1 (2000) – Storage, Class T1.2
• ETSI EN 300 019-2-2 (1999) – Transportation, Class T2.3
• ETSI EN 300 019-2-3 (2003) – Stationary Use at Weather-
• ETSI EN 300 019-2-2 (1999) – Transportation, Class T2.3
• ETSI EN 300 019-2-3 (2003) – Stationary Use at Weather-
protected Locations, Class T3.2
• ETSI EN 300 019-2-4 (2003) – Stationary Use at Non-weather
Protected Locations, Class 4.2H
• ETS 300753 (1997) – Acoustic Noise Emitted by
Telecommunications Equipment