IBM Flex System V7000 Expansion Enclosure 4939H29 ユーザーズマニュアル

製品コード
4939H29
ページ / 610
Chapter 12. Host Configuration 
513
Draft Document for Review January 29, 2013 12:52 pm
8068ch12-Host Config.fm
14.Click Manage Paths, select Round Robin as the multipath policy (Figure 12-60), and 
click Change
Figure 12-60   Change the multipath policy
15.Click Close twice to return to the storage view, and now the storage disk is available and 
ready to use for your VMware ESX server using an iSCSI attachment.
12.5  AIX Host Attachment
The following section details specific information that relates to the connection of AIX-based 
compute nodes in the IBM Flex System Enterprise Chassis attaching to the IBM Flex System 
V7000 Storage Node. The compute node models are the IBM Flex System p260 Compute 
Node and the IBM Flex System p460 Compute Node. At time of writing FCoE is not yet 
supported on AIX and we were unable to test iSCSI connectivity. This section detail FC 
connectivity only which is probably the most popular method of external block level storage 
connectivity for AIX and VIOS. In the examples below the AIX environment (or VIOS in 
oem_setup_env environment) CLI will be used. 
12.5.1  Configuring the AIX Compute Node for FC Connectivity
The following list outlines the steps required to attach IBM Flex System V7000 Storage Node 
volumes to an AIX host, creating these volumes and mapping the volumes to a host compute 
node have already been addressed in previous chapters.
1. Identify the HBAs in the AIX compute node.
2. Ensure that the correct AIX operating systems and version levels are installed on the 
compute node, including any updates and Authorized Program Analysis Reports (APARs) 
on the operating system.
3. Check connectivity of the AIX compute node to the FC switch I/O modules.