  DESCRIPTION, PURPOSE OF USE
 
•  19“ wall-mounted cabinet with IP20 protection
 
•  Three separate 19‘‘ sections
 
• Cabinet is to be hanged right on the wall.
 
• Cabinet includes two adjustable vertical rails in each section.
 • 
 
Cabinet 
construction:
  
 
– 
Welded 
frame
 
   –  Doors - a combination for different sections: safety hardened glass, thickness 4 mm (can be fully metal or 
perforated) solid steel and perforated
 
•  Max. permissible load of the door is 10 kg.
 
•  Min. thickness of the surface fi nish is 65 μm.
 
•  Cabinets are intended for installation of data and telecommunication devices and their distribution systems.
 
•  The frame of the cabinet and all the removable parts are connected with earthing cables that have to be properly 
fi xed and inserted into connectors during all the time when using the cabinet.
 
•  There is one M8 screw placed on the bottom part of the cabinet as an earthing main point.
 
•  Cable openings covered with breakout-type blanking panels are placed in the top and the bottom part of the 
cabinet rear side, others are in the top and the bottom side of cabinet..
 
•  Openings covered by break-out blanking panels, prepared for installation of cooling ventilators, are placed in the 
metal door of the fi rst section.
 OPERATION CONDITIONS
 • 
 
Operation 
environment:
  
 
– 
Offi ce
 
   –  The cabinet is not intended for outdoor installations and for installations in environment that can infl uence 
negatively the functionality of the cabinet and the mounted devices (e.g. environment with danger of explos-
ion or humid and wet surroundings)
 
•  Must be protected against:
  
 
– 
Mechanical 
damage
  
 
– 
Improper 
manipulation
 
   – A different usage than the cabinet is intended for
 
•  Improper manipulation is especially:
 
   – Overloading (maximum recommended load exceeding)
 
   –  Device installation that can infl uence negatively operation and function of the cabinet or the installed equipment
 
   – Change of the construction or design of the cabine
  INSTALLATION OF THE CABINET
 
•  Cabinet is to be hanged on the wall using the screws, dowels and washers (part of a supply). Spacing of holes 
designed for hanging is shown in the scheme.
 
•  To secure the maximum recommended load, it is necessary to fi x the cabinet on the wall with an appropriate 
carrying capacity (brick, concrete or similar) and to distribute the installed loading equally.
 
•  To avoid dust penetration in a case where cables lead through some of the cable openings, you can seal it using 
a blanking panel with a brush or secure by plastic frame (both are part of the cabinet supply).
 ENVIRONMENT PROTECTION
 
•  All parts are made of recyclable materials and after its discard, it is necessary to dispose the cabinet according 
to valid regulations.
 CERTIFICATE AND CONFORMITY
 
•  This product is fully in accordance with ČSN EN 62208 ed 2:2012.