Raritan PXE-1180C14R プリント

ページ / 2
Intelligent Metered Rack 
Power Distribution
PXE Intelligent Metered Power Distribution Units
800.724.8090 / +1 732.764.8886 / Fax +1 732.764.8887 / sales@raritan.com
PXE Series
Intelligent PDUs that give you more
control of power and cooling in the
data center.
• Remote power monitoring and
metering of current (amps), voltage,
power (kVA, kW) and energy 
consumption (kWh)
• Support for up to 16 environmental
sensors
• Power information from units, lines
and circuit breakers
• LED display
• Ethernet and USB-B access
• User customizable thresholds 
and alerts
• Alerts via SNMP, email, GSM SMS
(text) and SysLog when thresholds
are exceeded
• Supports HTTP, HTTPS, NTP, SMTP,
SSH, Telnet, SSL, and SNMP v1, 
v2 and v3, SNMP INFORMS, 
JSON-RPC
• Advanced authorization options,
including permissions, LDAP/S and
Active Directory
®
• Strong encryption and passwords
• Cisco EnergyWise™ compliant
• IPv6 support
• 1U and Zero U form factors
The Raritan PXE family of rack power distribution units (PDUs) offers real-time 
remote power monitoring of power at the inlet: RMS current per line (amps), 
RMS voltage per line pair, apparent and active power (kVA, kW), power factor 
and energy consumption (kWh). The PXE series comes in 1U and Zero U models, 
voltages from single phase 120V AC to three phase 208V AC, 15A to 50A and 
various combinations of IEC C-13, IEC C-19 and NEMA 5-20R outlets. 
Raritan power management solutions enable data center and facilities managers to:
Make informed capacity planning decisions
Efficiently utilize power resources
Improve uptime and staff productivity
Save power and money
Drive green data center initiatives
Monitor and manage power, energy 
and the data center environment
PXE offers accurate real-time power monitoring and metering. It provides 
alerts based on preset power and environment events. All PXEs are environment-
monitoring ready and accept Raritan’s plug-and-play environment sensors. 
The PXE intelligent rack PDU allows you to:
Find stranded power in racks
Load balance lines and circuits
Trend and track energy utilization 
Detect data center hot spots
Eliminate overcooling and increase temperature set points safely
Support hot aisle containment
The PXE has four ports. Ethernet (RJ-45) to connect it to a network. This 
connection is necessary to administer or access the PXE remotely using the 
Web interface. There are two small LEDs adjacent to the port: green indicates a
physical link and activity and yellow indicates communications at 10/100 BaseT
speeds. The sensor port (RJ-12) is used to connect Raritan’s optional environment
sensors. Users can specify environmental sensor location attributes. A USB-B port 
is used to establish a USB connection between a computer and the PXE. An 
RS-485 (RJ-45) is reserved for a future release.