Intel SC5400BRP ユーザーズマニュアル
Intel® Server Chassis SC5400 5U Kit TPS
Glossary
Revision: 1.0
93
Glossary
Word / Acronym
Definition
ACA
Australian Communication Authority
ANSI American
National Standards Institute
ATX
Advanced Technology Extended
Auto-Ranging
Power supply that automatically senses and adjust itself to the proper input voltage range
(110 VAC or 220 VAC). No manual switches or manual adjustments are needed.
(110 VAC or 220 VAC). No manual switches or manual adjustments are needed.
BMC
Baseboard Management Controller
CFM
Cubic Feet per Minute (airflow)
CMOS
Complementary Metal Oxide Silicon
Dropout
A condition that allows the line voltage input to the power supply to drop to below the
minimum operating voltage.
minimum operating voltage.
EEB Entry
E-Bay
EMP
Emergency Management Port
FP Front
Panel
FRB
Fault Resilient Booting
FRU
Field Replaceable Unit
HSBP
Hot Swap Backplane
Latch Off
A power supply, after detecting a fault condition, shuts itself off. Even if the fault condition
disappears the supply does not restart unless manual or electronic intervention occurs.
Manual intervention commonly includes briefly removing and then reconnecting the supply, or
it could be done through a switch. Electronic intervention could be done by electronic signals
in the Server System.
disappears the supply does not restart unless manual or electronic intervention occurs.
Manual intervention commonly includes briefly removing and then reconnecting the supply, or
it could be done through a switch. Electronic intervention could be done by electronic signals
in the Server System.
LCD
Liquid Crystal Display
LCP
Local Control Panel
LPC Low-Pin
Count
Monotonically
A waveform changes from one level to another in a steady fashion, without intermediate
retrenchment or oscillation.
retrenchment or oscillation.
MTBF
Mean Time Between Failure
MTTR
Mean Time to Repair
Noise
The periodic or random signals over frequency band of 10 Hz to 20 MHz.
OTP
Over Temperature Protection
Over-current
A condition in which a supply attempts to provide more output current than the amount for
which it is rated. This commonly occurs if there is a ‘short circuit’ condition in the load
attached to the supply.
which it is rated. This commonly occurs if there is a ‘short circuit’ condition in the load
attached to the supply.
OVP
Over Voltage Protection
PDB
Power Distribution Board
PFC
Power Factor Correction
PSU
Power Supply Unit
PWOK
A typical logic level output signal provided by the supply that signals the Server System that
all DC output voltages are within their specified range
all DC output voltages are within their specified range
RI Ring
Indicate
Ripple
The periodic or random signals over frequency band of 10 Hz to 20 MHz.
Rise Time
Rise time is defined as the time it takes any output voltage to rise from 10% to 95% of its
nominal voltage.
nominal voltage.
Sag
The condition where the AC line voltage drops below the nominal voltage conditions
SAS
Serial Attached SCSI