Intel SC5299WS ユーザーズマニュアル

ページ / 154
Peripheral and Hard Drive Support 
Intel
®
 Entry Server Chassis SC5299-E TPS 
  
Revision 
3.1 
Intel order number D37594-005 
108 
Thermal performance of specific devices must be verified to ensure compliance to the 
manufacturer’s specifications.  
The 5.25-in peripherals can be inserted and removed without tools from the front of the chassis 
after taking off the access cover and removing the front bezel. The peripheral bay utilizes visual 
guide holes to correctly line up the position of peripheral drives. Locking slide levers push 
retaining pins into the drive to hold it securely in the bay. EMI shield panels are installed and 
should be retained in unused 5.25-in bays to ensure proper cooling and EMI conformance. 
Note: Use caution when approaching the maximum level of integration for the 5.25-in drive 
bays. Power consumption of the devices integrated needs must be carefully considered to 
ensure that the maximum power levels of the power supply are not exceeded.  
4.3  Hard Disk Drive Bays 
4.3.1 
Fixed Hard Drive Bay 
The Intel
®
 Entry Server Chassis SC5299-E comes with a removable hard drive bay that can 
accept up to six cabled 3.5-in x 1-in hard drives. Power requirements for each individual hard 
drive may limit the maximum number of drives that can be integrated into an Intel
®
 Entry Server 
Chassis SC5299-E. The drive bay is designed to allow adequate airflow between drives, and no 
additional cooling fan is required. Drives must be installed in the order of slot 1, 3, 5 first 
(skipping slots) to ensure proper cooling. The drive bay is secured with a tool-less retention 
mechanism.  
Note: The hard drive bay must be pushed forward or removed to install the server board.  
TP00873
 
Figure 23. 6-HDD Fixed Drive Bay, Rear Isometric View