Brocade VDX 6740 BR-VDX6740-64-F データシート
製品コード
BR-VDX6740-64-F
Management
Management and control
• IPv4/IPv6 management
• Industry-standard Command Line Interface (CLI)
• Remote lights out management (future update)
• Link Layer Discovery Protocol (LLDP) IEEE 802.1AB
• Logical chassis management
• MIB II RFC 1213 MIB
• Switch Beaconing
• Switched Port Analyzer (SPAN)
• Telnet
• SNMP v1, v2C, v3
• sFlow RFC 3176
• Industry-standard Command Line Interface (CLI)
• Remote lights out management (future update)
• Link Layer Discovery Protocol (LLDP) IEEE 802.1AB
• Logical chassis management
• MIB II RFC 1213 MIB
• Switch Beaconing
• Switched Port Analyzer (SPAN)
• Telnet
• SNMP v1, v2C, v3
• sFlow RFC 3176
• Out-of-band management
• Remote SPAN (RSPAN)
• RMON-1, RMON-2
• NTP
• Management Access Control Lists (ACLs)
• Role-Based Access Control (RBAC)
• Range CLI support
• UDLD
• Netconf API
• Brocade VCS Plugin for OpenStack
• Remote SPAN (RSPAN)
• RMON-1, RMON-2
• NTP
• Management Access Control Lists (ACLs)
• Role-Based Access Control (RBAC)
• Range CLI support
• UDLD
• Netconf API
• Brocade VCS Plugin for OpenStack
Security
• Port-based Network Access Control 802.1X
• RADIUS
• TACACS+
• Secure Shell (SSHv2)
• RADIUS
• TACACS+
• Secure Shell (SSHv2)
• BPDU Drop
• Lightweight Directory Access Protocol (LDAP)
• Secure Copy Protocol
• Lightweight Directory Access Protocol (LDAP)
• Secure Copy Protocol
Mechanical
Enclosure
Front-to-rear, rear-to-front airflow; 1U, 19-inch EIA-compliant; power from non-port side
Environmental
Temperature
Operating: 0°C to 40°C (32°F to 104°F)
Non-operating and storage: −25°C to 70°C (−13°F to 158°F)
Non-operating and storage: −25°C to 70°C (−13°F to 158°F)
Humidity
Operating: 10% to 85% non-condensing
Non-operating and storage: 10% to 90% non-condensing
Non-operating and storage: 10% to 90% non-condensing
Altitude
Operating: Up to 3,048 meters (10,000 feet)
Non-operating and storage: Up to 12 kilometers (39,370 feet)
Non-operating and storage: Up to 12 kilometers (39,370 feet)
Shock
Operating: 20 G, 11 ms half-sine
Non-operating and storage: Square wave, 44 G, 15 ms
Non-operating and storage: Square wave, 44 G, 15 ms
Vibration
Operating: 0.5 G peak, 0.7 G ms random, 5 to 500 Hz
Non-operating and storage: 2.0 g sine, 1.4 G rms random, 5 to 500 Hz
Non-operating and storage: 2.0 g sine, 1.4 G rms random, 5 to 500 Hz
Airflow
Brocade VDX 6740 port-side-intake and port-side-exhaust:
Maximum: 25.7 CFM
Nominal: 11.5 CFM
Brocade VDX 6740T port-side-intake:
Maximum: 49.3 CFM
Nominal: 26.3 CFM
Brocade VDX 6740T port-side-exhaust:
Maximum: 51.9 CFM
Nominal: 27.3 CFM
Maximum: 25.7 CFM
Nominal: 11.5 CFM
Brocade VDX 6740T port-side-intake:
Maximum: 49.3 CFM
Nominal: 26.3 CFM
Brocade VDX 6740T port-side-exhaust:
Maximum: 51.9 CFM
Nominal: 27.3 CFM
Heat dissipation
1672.41 BTU/hr
Power
Power supplies
Two internal, redundant, field-replaceable, load-sharing AC power supplies
Power inlet
C13
Input voltage
85 to 264 VAC nominal
Input line frequency
50 to 60 Hz
Inrush current
Limited to 30 A peak at 240 VAC during cold startup at 25°C ambient
Maximum current
6 A max at 100 VAC/60 Hz
Maximum power consumption
Brocade VDX 6740: 110 W
Brocade VDX 6740T: 420 W
Brocade VDX 6740T-1G: 276 W (Base SKU)
Brocade VDX 6740T: 420 W
Brocade VDX 6740T-1G: 276 W (Base SKU)
Safety Compliance
• CAN/CSA C22.2 No. 60950-1-07 including
A1 / UL 60950-1-07, Ed. 2 including A1
• CAN/CSA-C22.2 No. 60950-1 Second Edition
• EN 60950-1 Second Edition +A1/A12
• EN 60950-1 Second Edition +A1/A12
• IEC 60950-1 Second Edition +A1
• GB 4943.1-2011 and GB9254-2008
• CNS14336-1(99)
• GB 4943.1-2011 and GB9254-2008
• CNS14336-1(99)