Installation manual Integral 5 D/E easy
Installation examples I5 E easy
Explanation of example 5
The example shows a mixture of attached items.
Certain restrictions apply here:
All modules must be earthed.
Max. 32 x RBS are permissible within the system (in the example there are 32 x RBS).
No S8D modules are permitted on the BNE and BNS control modules.
One plug-in mains unit supplies 1 x BNx plus 1 x EXE, or 2 x EXE.
One module with DECT module(s) requires its own power supply.
An EXE with one LAN module attached, requires only one IOM connection
(See previous diagram, upper).