Cisco SFS 7012D InfiniBand Server Switch SFS-7012D データシート
製品コード
SFS-7012D
All contents are Copyright © 1992–2006 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information.
Page 4 of 6
Cisco SFS 7012D
Cisco SFS 7024D
Line Interface Module
●
Up to 12 per system
●
12 dual-speed DDR/SDR 4X InfiniBand Ports
●
Supports hot-pluggable optical media converter on a
port-by-port basis
●
Physical connection and traffic LEDs for each port
●
Hot-swappable FRU
●
Port status, operation status, and alert LEDs
●
Up to 24 per system
●
12 dual-speed DDR/SDR 4X InfiniBand Ports
●
Supports hot-pluggable optical media converter on a
port-by-port basis
●
Physical connection and traffic LEDs for each port
●
Hot-swappable FRU
●
Port status, operation status, and alert LEDs
Power Supply
●
Up to 6 per system
●
Redundant, hot-swappable FRU
●
350W per power supply
●
Operation status and alert LEDs
●
Up to 12 per system
●
Redundant, hot-swappable FRU
●
350W per power supply
●
Operation status and alert LEDs
Fan Module
●
Up to 4 fan trays (2 fans per tray) per system
●
Cooling: front to back
●
Redundant, hot-swappable FRU
●
Operation status and alert LEDs
●
Up to 8 fan trays (2 fans per tray) per system
●
Cooling: front to back
●
Redundant, hot-swappable FRU
●
Operation status and alert LEDs
Table 2.
Mechanical Specifications
Cisco SFS 7012D
Cisco SFS 7024D
Mounting
Mountable in a standard 19-inch Electronic Industries Alliance (EIA) rack
Mountable in a standard 19-inch EIA rack
Size
●
Standard 19-inch rack-mountable
●
7RU height (12.25 inches)
●
25.75-inch depth
●
Standard 19-inch rack-mountable
●
14RU height (24.5 inches)
●
25.75-inch depth
Air Flow
Front to back
Front to back
Weight
65–110 lbs, based on configuration
100–200 lbs, based on configuration
Table 3.
Environmental Specifications
Cisco SFS 7012D
Cisco SFS 7024D
Temperature
●
Operating: 50 to 113°F (10 to 45°C)
●
Storage: –40 to 167°F (-40 to 75°C)
●
Operating: 50 to 113°F (10 to 45°C)
●
Storage: –40 to 167°F (-40 to 75°C)
Altitude
●
Operating: 10,000 ft
●
Storage: 40,000 ft
●
Operating: 10,000 ft
●
Storage: 40,000 ft
Humidity
●
Operating: 20 to 80% non-condensing
●
Storage: 5 to 90% non-condensing
●
Operating: 20 to 80% non-condensing
●
Storage: 5 to 90% non-condensing
Shock
●
Operating: 5G maximum, 11 ms half-sine wave; 10G
maximum, 5 ms half-sine wave
●
Storage: 10G maximum, 11 ms half-sine wave
●
Operating: 5G maximum, 11 ms half-sine wave; 10G maximum,
5 ms half-sine wave
●
Storage: 10G maximum, 11 ms half-sine wave
Vibration
●
Operating: 0.50G maximum, 3–200 Hz, 15 min (Sinusoidal);
1.02Grms, 3-axis, bottom/top, left/right, front/back (random)
●
Storage: 0.50G maximum, 3–200 Hz, 15 min (Sinusoidal);
2.09Grms, 3-axis, bottom/top, left/right, front/back (random)
●
Operating: 0.50G maximum, 3–200 Hz, 15 min (Sinusoidal);
1.02Grms, 3-axis, bottom/top, left/right, front/back (random)
●
Storage: 0.50G maximum, 3–200 Hz, 15 min (Sinusoidal);
2.09Grms, 3-axis, bottom/top, left/right, front/back (random)
Power
●
90–264 V AC automatic-ranging, 47-63 Hz, 350W maximum
per power supply
●
90–264 V AC automatic-ranging, 47–63 Hz, 350W maximum
per power supply