Cisco SFS 7012D InfiniBand Server Switch SFS-7012D データシート

製品コード
SFS-7012D
ページ / 6
 
All contents are Copyright © 1992–2006 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. 
Page 4 of 6 
 
Cisco SFS 7012D 
Cisco SFS 7024D 
Line Interface Module 
  Up to 12 per system 
  12 dual-speed DDR/SDR 4X InfiniBand Ports 
  Supports hot-pluggable optical media converter on a 
port-by-port basis 
  Physical connection and traffic LEDs for each port 
  Hot-swappable FRU 
  Port status, operation status, and alert LEDs 
  Up to 24 per system 
  12 dual-speed DDR/SDR 4X InfiniBand Ports 
  Supports hot-pluggable optical media converter on a 
port-by-port basis 
  Physical connection and traffic LEDs for each port 
  Hot-swappable FRU 
  Port status, operation status, and alert LEDs 
Power Supply 
  Up to 6 per system 
  Redundant, hot-swappable FRU 
  350W per power supply 
  Operation status and alert LEDs 
  Up to 12 per system 
  Redundant, hot-swappable FRU 
  350W per power supply 
  Operation status and alert LEDs 
Fan Module 
  Up to 4 fan trays (2 fans per tray) per system 
  Cooling: front to back 
  Redundant, hot-swappable FRU 
  Operation status and alert LEDs 
  Up to 8 fan trays (2 fans per tray) per system 
  Cooling: front to back 
  Redundant, hot-swappable FRU 
  Operation status and alert LEDs 
Table 2. 
Mechanical Specifications 
 
Cisco SFS 7012D 
Cisco SFS 7024D 
Mounting 
Mountable in a standard 19-inch Electronic Industries Alliance (EIA) rack 
Mountable in a standard 19-inch EIA rack 
Size 
  Standard 19-inch rack-mountable 
  7RU height (12.25 inches) 
  25.75-inch depth 
  Standard 19-inch rack-mountable 
  14RU height (24.5 inches) 
  25.75-inch depth 
Air Flow 
Front to back 
Front to back 
Weight 
65–110 lbs, based on configuration 
100–200 lbs, based on configuration 
Table 3. 
Environmental Specifications 
 
Cisco SFS 7012D 
Cisco SFS 7024D 
Temperature 
  Operating: 50 to 113°F (10 to 45°C) 
  Storage: –40 to 167°F (-40 to 75°C) 
  Operating: 50 to 113°F (10 to 45°C) 
  Storage: –40 to 167°F (-40 to 75°C) 
Altitude 
  Operating: 10,000 ft 
  Storage: 40,000 ft 
  Operating: 10,000 ft 
  Storage: 40,000 ft 
Humidity 
  Operating: 20 to 80% non-condensing 
  Storage: 5 to 90% non-condensing 
  Operating: 20 to 80% non-condensing 
  Storage: 5 to 90% non-condensing 
Shock 
  Operating: 5G maximum, 11 ms half-sine wave; 10G 
maximum, 5 ms half-sine wave 
  Storage: 10G maximum, 11 ms half-sine wave 
  Operating: 5G maximum, 11 ms half-sine wave; 10G maximum, 
5 ms half-sine wave 
  Storage: 10G maximum, 11 ms half-sine wave 
Vibration 
  Operating: 0.50G maximum, 3–200 Hz, 15 min (Sinusoidal); 
1.02Grms, 3-axis, bottom/top, left/right, front/back (random) 
  Storage: 0.50G maximum, 3–200 Hz, 15 min (Sinusoidal); 
2.09Grms, 3-axis, bottom/top, left/right, front/back (random) 
  Operating: 0.50G maximum, 3–200 Hz, 15 min (Sinusoidal); 
1.02Grms, 3-axis, bottom/top, left/right, front/back (random) 
  Storage: 0.50G maximum, 3–200 Hz, 15 min (Sinusoidal); 
2.09Grms, 3-axis, bottom/top, left/right, front/back (random) 
Power 
  90–264 V AC automatic-ranging, 47-63 Hz, 350W maximum 
per power supply 
  90–264 V AC automatic-ranging, 47–63 Hz, 350W maximum 
per power supply