Axis PS-A UK 12866 ユーザーズマニュアル

製品コード
12866
ページ / 29
 
Management and Configuration
 
AXIS 540/640 User’s Guide
 
26
 
Using the Test Button
The following operations can be performed by pressing the test button in different 
sequences. Please refer to Product Overview, on page 5, to identify the location of the 
test button.
Printing a test page:
• Press the test button once to print a test page.
Printing the parameter list:
• Press the test button twice to print the parameter list.
Resetting the AXIS 540/640 parameters to the factory default settings:
1. Remove the external power supply to switch off the AXIS 540/640.
2. Press and hold down the test button, while you reconnect the external power 
supply. Continue to hold down the test button until the network indicator starts 
to flash at one second intervals. This should take about 5 seconds.
3. Release the test button and wait until the network indicator flashes at least five 
times.
4. Press and hold down the test button again until the network indicator remains 
constantly lit.
5. Restart the AXIS 540/640 by disconnecting and reconnecting the external power 
supply.
Note:
Please refer to the AXIS 540/640 User’s Manual for more information about the test 
button.
All parameters except the node address (NODE_ADDR.), the IP address (IP_ADDR.) and DHCP 
enabled or disabled (DHCP_ENABLE.) are reset.