Technical specifications
Electrical
Power Supply
24 VAC 50/60 Hz
12 VDC 
Power-over-Ethernet 48 VDC nominal
Current Consumption
1 A (12 VDC)
0.8 A (24 VAC)
0.3 A (PoE 48 VDC)
Power Consumption
12 W
PoE
IEEE 802.3af (802.3at Type 1)
 
Sensor
Type
1/3‑inch CMOS HD
Sensor Pixels
1312 x 1069 (1.4MP)
Video
Video compression
H.264 (ISO/IEC 14496-10); M- JPEG,
JPEG
Streaming
Multiple configurable streams in H.264
and M-JPEG, configurable frame rate and
bandwidth.
Regions of Interest (ROI)
Overall IP Delay
Min. 120 ms, Max. 240 ms
GOP structure
IP, IBP, IBBP
Encoding interval
1 to 60 (50) ips
 
 
Resolutions (H x V)
• 720p HD
1280 x 720
• D1 4:3 (cropped)
704 x 480
• SD upright
(cropped)
400 x 720
• 480p SD
Encoding: 704 x 480;
Displayed: 854 x 480
• 432p SD
768 x 432
• 288p SD
512 x 288
• 240p SD
Encoding: 352 x 240;
Displayed: 432 x 240
• 144p SD
256 x 144
Sensitivity (3200 K, scene reflectivity 89%, F1.2)
 
Minimum illumination (30 IRE)
Color
0.017 lx (0.0017 fc)
Monochrome
0.0057 lx (0.00057 fc)
Day/Night
Color, Monochrome, Auto
White Balance
ATW (2500 to 10000K), ATWhold and
manual
Indoor and Outdoor ATW
Shutter
Automatic Electronic Shutter (AES)
Fixed (1/30 [1/25] to 1/150000)
selectable
Default shutter
Backlight compensation
(IVA)
Off, Auto, IntelligentAE (iAE)
Backlight compensation
(non IVA)
Off, Auto, BLC
Noise reduction
Intelligent Dynamic Noise Reduction
(iDNR) with separate temporal and spatial
adjustments
Contrast enhancement
On/off
Sharpness
Sharpness enhancement level selectable
Dynamic range
84 dB WDR
100 dB WDR (with iAE)
Privacy Masking
Four independent areas, fully
programmable
Video Motion Analysis
Intelligent Video Analysis
 
Audio
Standard
AAC
G.711, 8kHz sampling rate
L16, 16kHz sampling rate
Signal-to-noise ratio
> 50 dB
Audio Streaming
Full duplex / half duplex
Input/output
Analog Video out
(service only)
CVBS (PAL/NTSC), 1 Vpp, 2.5 mm jack,
75 Ohm (non-protected)
Audio
1 x mono line in, 1 x mono line out
• connector
3.5 mm stereo jack
• signal line in
12 kOhm typical, 1 Vrms max
• signal line out
1 Vrms at 1.5 kOhm typical,
Alarm
2 inputs
• activation
voltage
+5 VDC to +40 VDC
(+3.3 VDC with DC-coupled 22 kOhm pull-
up resistor)
Relay
1 output
• voltage
30 VAC or +40 VDC max.
Maximum 0.5 A continuous, 10VA
6 | FLEXIDOME IP starlight 7000 RD