Brand-Rex 5.0m RJ45 Cat5e UTP GPCPCU050-555H ユーザーズマニュアル

製品コード
GPCPCU050-555H
ページ / 63
AC6
500
MHz
1 . 5
Brand-Rex Copper Cables - 10GPlus
Communication Cable, U/UTP, 100 Ω, 4x2,AWG23/1
Designed to be compliant with the following draft standards:
•  ISO 11801:2002 Amm1.1, ISO 61156-5 ed 2,
EN 50173-1 ed2 EN 50288-10-1, ANSI/TIA/EIA 568B.2-10
Cable Standards
The cable is backwards compatible with:
•  ISO 11801:2002, ISO 61156-5, EN 50173-1:2002, EN 50288-
6-1, ANSI/TIA/EIA 568B, ANSI/TIA/EIA 568B.2-1
Augmented Category 6 Systems
PRODUCT DESCRIPTION
10GPlus U/UTP, 100 Ohm, 4x2,AWG23/1 is a 
premium grade Class EA / Augmented Category 6 
cable to support 10 Gigabit Ethernet protocol for 
installation in horizontal and backbone 
applications.
PRODUCT PERFORMANCE
Core
Conductor:   23 AWG Plain Annealed
Copper Wire
Insulation:
Polyolefin
Diameter:
1.06mm Nominal
Pair:
2 of the above cores
Pair Colour:   Blue - White, Orange - White,
Green - White, Brown - White
Final Assembly
Cable: 
 4 of the above pairs cabled together 
around a cross filler
Sheath:
PVC or LSZH compound
Mechanical and Environmental
Temp - Installation:
0C to 50C
Temp - Operation:
-20C to 75C
Max Tensile Load:
10kg per cable
Min Bend Radius:
8 x Effective Diametre (installation)
Min Bend - Operation: 
4 x Effective Diametre (operation)
Packaging
WRL 
 500m Wooden Reel 4 per Pallet
1000m Wooden Reel 2 per Pallet
Max 19Ω / 100m
Max 2%
1.0kV dc or 0.7kV ac for 1 min
>500 MΩ.km @ 100-500 V test voltage
<120 pF/100m
<534 nsec/100m @ 100Mhz
Max 40ns/100m @ 100Mhz
100+/-5 Ω @ 100Mhz
Min 40dB
Max 19Ω / 100m
0.5%
100% in process test
>5 GΩ.km
40 pF/100m
<490 nsec/100m @ 100Mhz (NVP for hand testers = 0.67)
Max 30ns/100m @ 100Mhz
100+/-5 Ω @100Mhz
56dB
Conductor Loop Resistance
Conductor Resistance Unbalance
Dielectric Strength
Insulation Resistance
Capacitance Unbalance to Earth
Velocity of Propagation
Skew
Mean Characteristic Impendance
Coupling Attenuation up to 1Ghz
Electrical Characteristics @ 20°c
Specification
Typical Performance
Return Loss
Insertion Loss
NEXT
PSNEXT
ELFEXT
PSELFEXT
PSANEXT
PSAELFEXT
Characteristic
Typical Headroom vs Cat6 (250MHz)
Typical Headroom vs AC6 (500MHz)
5dB
6%
10dB
10dB
12dB
12dB
NA
NA
5dB
2%
10dB
20dB
12dB
12dB
5dB
6dB
Part Number
Outer Sheath
Construction
Cable Weight
Calorific Value
Effective Diameter
Sheath Colour
Fire Safety Rating
Acid Gas Emmisons
Smoke Index
Packaging Unit
AC6U - HF1
LSZH
Simplex
79 kg/km
32 kJ/m
8.5mm
Voilet RAL 4005
IEC 60332 - Part 1
IEC 60754 - 1
IEC 61034
WRL
AC6U - HF3
LSZH
Simplex
81 kg/km
41 kJ/m
8.5mm
Blue RAL 5015
IEC 60332 - Part 3c
IEC 60754 - 1
IEC 61034
WRL
* Power Sum Attenuation to Alien Crosstalk (near end) Ratio
The Alien crosstalk performance of cables is assessed using
a ‘6 round 1’ or ‘4 on a drum’ method.
Sheath
Cross Filler
23 AWG PACW
Polyolefin Insulation
PSACR @ 500MHz
PSAACR* @ 500MHz
Typical headroom on key S/N characteristics - for information only
NA
NA
0dB
13dB
Typical Headroom vs Cat6 (250MHz)
Typical Headroom vs AC6 (500MHz)