DRY CONTACT APPLICATION (USING DIP SWITCH) 
The dry contact system enables the operation of the air conditioner indoor unit to be controlled by using external dry contacts 
(with non voltage) such as card-key controller or window for facilities such as hotels. 
 
Table 1 (Applicable models and related information) 
Optional Connecting cord Accessory SPX-WDC# 
Model 
DIP SW Label 
CN# 
 
 
 
 
 
SPX-WDC1  RAK-18/25/35PSPA 
DSW1 
CN6 
RAK-25/35/50PXA 
DSW1 
CN6 
RAK-18/25/35PPA 
DSW1 
CN6 
RAK-50/60/70PPA 
SW501 
CN6 
RAK-18/25/35/50PEA 
DSW1 
CN6 
RAK-18/25/35/50QXA 
DSW1 
CN6 
RAK-18/25/35/50QPA 
SW501 
CN6 
RAF-25/35/50PXA 
DIP-SW 
CN6 
RAF-25/35/50QXA 
DIP-SW 
CN6 
RAF-25/35/50RPA 
DSW1 
CN6 
SPX-WDC2  RAD-25/35/50RPA 
SW501 
CN9 
RAD-50/60/70PPA 
SW501 
CN9 
RAI-25/35/50RPA 
SW501 
CN9 
 
Note: 
1) DRY CONTACT function is "Enable" by set pin No. 2 of the DIP SWITCH (refer to table 1 for the label) to ON position. 
2) Select the proper setting for DRY CONTACT LOGIC INPUT pin No. 3 on DIP SWITCH (refer to Table 1 for the label) 
i) Set to OFF position (Hi Input) if the type of Dry Contact switch to be used (for the CARD KEY UNIT or Window) is of 
contact type a (Normally Open Type) as shown in below diagram.   
ii) Set to ON position (Lo Input) if the type of Dry contact switch to be used (for the CARD KEY UNIT or Window) is of contact 
type b (Normally Close Type) as shown in below diagram. 
 
ON 
 
 
OFF 
 
 
Pin No. 
Function 
Switch Position / Setting 
DRY CONTACT function  OFF 
Disable 
ON 
Enable 
DRY CONTACT Input Logic  OFF  HI Input Active  ON  LO Input Active 
 
 
DIP SW Label 
Main PWB side 
(CN# terminal) 
Dry Contact side 
(no polarity) 
Connecting cord 
SPX-WDC#