10-8
 
 
 
 CAUTION 
• 
A circuit breaker or fuse must be installed. Without a 
circuit breaker or fuse, the danger of electric shock 
exists. A main switch with a contact gap of more 
than 3.5mm has to be installed in the power supply 
line to the outdoor unit. 
• 
Do not install the unit near a location where there is 
a flammable gas. The indoor unit may catch fire if 
flammable gas leaks around it. 
• 
Be sure to tighten the flare nut to the specified 
torque using a torque wrench. If the flare nut is 
tightened excessively, it may crack as time elapses, 
causing the refrigerant leakage. 
• 
Please ensure  smooth flow of water when installing 
the drain hose. 
• 
Piping shall be suitable supported with a maximum 
spacing of 1m between supports 
• 
An IEC approved power cord should be used. Power 
cord type: NYM. 
 
 WARNING
 
• 
The unit should be mounted at stable, non-vibratory 
location which can provide full support to the unit. 
 CAUTION 
• 
No nearby heat source and no obstruction near the 
air outlet is allowed. 
• 
The clearance distances from top right and left are 
specified in figure below. 
• 
The location must be convenient for water drainage 
and pipe connection with the Outdoor unit. 
• 
To avoid interference from noise, please place the 
unit and its remote controller at least 1m from the 
radio, television and inverter type fluorescent lamp. 
• 
To avoid any error in signal transmission form the 
remote controller, please put the controller far away 
from high-frequency machines and high-power 
wireless systems. 
Indoor unit installation 
 
 
Installation of wall penetration and installation of 
protection pipe 
 
1.  Hole position 
Make a hole on the wall such the position as shown below, 
in order to keep the flow for condensed water smooth. 
Hole position 
In case of making a hole 
on the wall 
In case of making a hole 
on the floor 
 
 
 
2.  Wall penetration and installation of protection pipe 
Drill a 
Φ65mm hole on wall which is slightly tilted towards 
the outdoor side. Drill the wall at a small angle. 
Cut the protection pipe according to the wall thickness. 
Empty gap in the sleeve of protection pipe should be 
completely sealed with putty to avoid dripping of rain water 
into the room. 
 
 CAUTION 
• 
Be sure that the wire is not in contact with any metal 
in the wall. Please use the protection pipe as wire 
passing through the hollow part of the wall so as to 
prevent the possibility of damaged by mouse. 
Models: Floor 
type 
Maximum 
piping length 
(m) 
Minimum 
piping 
length (m) 
Maximum 
height (m) 
RAF-25PXA 
10 
20 
RAF-35PXA 
10 
20 
RAF-50PXA 
10 
30 
The space indicated by an arrow is to guarantee the 
performance of the air conditioner. Install the apparatus at 
the ample space in order to carry out the maintenance and 
repair works. 
 
Be sure to 
completely seal the 
gap with putty. 
 
When mounting 
on a wall (up to 
150-500mm from 
the floor surface). 
 
The indoor piping should be 
insulated with the enclosed 
insulation pipe. (If the insulation is 
insufficient, please use commercial 
products). 
 
Drain hose 
to be lower 
than center 
of hole 
55mm 
184
m
m
 o
r less
 
65mm 
80~
100m
m
 
Outdoor 
Indoor 
Seal with 
putty 
2~5mm 
Seal with 
putty 
Protection 
pipe 
Sleeve of 
protection 
pipe