Hitachi RAC-25WPA RAC25WPA ユーザーズマニュアル
製品コード
RAC25WPA
UNITS INSTALLATION
10-42
Figure showing the Installation of Outdoor unit
Operation space, Length and Height difference
Operation space, Length and Height difference
Single
split
Models:
Ⓐ
(m)
Ⓑ
(m)
Ⓒ
(m)
Ⓓ
(m)
Ⓔ
(m)
Ⓕ
(m)
Ⓖ
(m)
Ⓗ
(m)
RAC-18WSA
>0.2 >0.2 >0.05
>0.1
>0.2
20 5 10
RAC-25WSA
>0.2 >0.2 >0.05
>0.1
>0.2
20 5 10
RAC-35WSA
>0.2 >0.2 >0.05
>0.1
>0.2
20 5 10
RAC-18WSAN
>0.3 >0.2 >0.05
>0.1
>0.2
20 5 10
RAC-25WSAN
>0.3 >0.2 >0.05
>0.1
>0.2
20 5 10
RAC-35WSAN
>0.2 >0.2 >0.05
>0.1
>0.2
30 5 10
RAC-18WSPA
>0.3 >0.2 >0.05
>0.1
>0.2
20 5 10
RAC-25WSPA
>0.3 >0.2 >0.05
>0.1
>0.2
20 5 10
RAC-35WSPA
>0.2 >0.2 >0.05
>0.1
>0.2
30 5 10
RAC-25WXA
>0.3 >0.2 >0.05
>0.1
>0.2
20 5 10
RAC-35WXA
>0.3 >0.2 >0.05
>0.1
>0.2
20 5 10
RAC-50WXA
>0.2 >0.2 >0.05
>0.1
>0.2
30 5 10
RAC-18WPA
>0.4 >0.2 >0.15
>0.1
>0.2
20 5 10
RAC-25WPA
>0.4 >0.2 >0.15
>0.1
>0.2
20 5 10
RAC-35WPA
>0.3 >0.2 >0.05
>0.1
>0.2
20 5 10
RAC-50WPA
>0.7 >0.2 >0.1
>0.1
>0.2
20 3 10
RAC-60WPA
>0.7 >0.2 >0.1
>0.1
>0.2
30 3 20
RAC-70WPA
>0.7 >0.2 >0.1
>0.1
>0.2
30 3 20
RAC-18WEA
>0.4 >0.2 >0.15
>0.1
>0.2
20 5 10
RAC-25WEA
>0.4 >0.2 >0.15
>0.1
>0.2
20 5 10
RAC-35WEA
>0.3 >0.2 >0.05
>0.1
>0.2
20 5 10
RAC-50WEA
>0.2 >0.2 >0.05
>0.1
>0.2
20 5 10
CAUTION
Indoor unit 1
Indoor unit 1
Outdoor unit
Outdoor unit
Maximum
pipe height
Ⓗ
pipe height
Ⓗ
Maximum
pipe length Ⓕ
pipe length Ⓕ
Minimum
pipe length
Ⓖ
pipe length
Ⓖ
Give clearance
as wide as
possible
as wide as
possible