Hitachi RAC-25WPA RAC25WPA ユーザーズマニュアル

製品コード
RAC25WPA
ページ / 706
 
12-5 
 
12.5  DRAIN PUMP 
12.5.1  BUILD IN DRAIN PUMP 
The air conditioner is equipped with an internal drain pump 
to remove accumulated condensation water from drain pan 
even while it is operating. A float switch 
• 
Monitors the water level and automatically activates 
the pump as necessary. 
 
*Applicable for 
ceiling cassette 
type indoor and 
duct type indoor 
only. 
 
12.5.2  SPECIFICATION OF DRAIN PUMP 
Applicable models 
RAI-25RPA, RAI-35RPA, RAI 
50RPA 
RAD-18RPA, RAD-25RPA, 
RAD-35RPA, RAD-50RPA 
RAD-50PPA, RAD-60PPA, 
RAD-70PPA 
Fluid 
Water 
Water 
Water 
Fluid temperature
 o
0 ~ 40 
0 ~ 40 
0 ~ 40 
Ambient temperature
 o
0 ~ 40 
0 ~ 40 
-10 ~ 50 
Max humidity % 
95 and below 
95 and below 
95 and below 
Storage temperature 
o
-10~70
o
-10~70
o
-20~80
o
Mounting direction 
Shall be install upward  
Slanting gradient should be 
less than 5 degree 
Shall be install upward  
Slanting gradient should be 
less than 5 degree 
Shall be install upward  
Slanting gradient should be 
less than 10 degree 
Motor type 
DC brushless motor 
(insulation class E) 
DC brushless motor 
(insulation class E) 
DC 2-pole motor 
(insulation class E) 
Maximum lift 
Lift 300mm water in rated 
voltage 
Lift 300mm water in rated 
voltage 
Lift 500mm water in rated 
voltage 
Minimum water level 
8mm 
8mm 
6mm 
Noise  
45dB max 
45dB max 
37dB max 
Insulation resistance 
100M
Ω at DC500V 
100M
Ω at DC500V 
100M
Ω at DC500V 
Life span 
Operate continuously up to 
10,000 hours, under 300mm 
lift, 10mm water level, rated 
voltage, and rated water 
temperature 
Operate continuously up to 
10,000 hours, under 300mm 
lift, 10mm water level, rated 
voltage, and rated water 
temperature 
Operate continuously up to 
15,000 hours, under 500mm 
lift, 10mm water level, rated 
voltage, and rated water 
temperature 
12.6  CONDENSED WATER DISPOSAL OF 
OUTDOOR UNIT 
• 
There are holes on the base of Outdoor unit for 
condensed water to discharge 
• 
In order to drain out the condensed water, the unit 
is installed on a stand or a block so that the unit is 
100mm above the ground as the shown figure. 
Join the drain pipe to one hole. 
• 
At first insert one portion of the hook to the base 
(Portion A), then pull the drain pipe in the direction 
shown by the arrow while inserting the hook into 
the base. After installation, check whether the 
drain pipe cling to the base firmly. 
 
 
 
 
When Use and Install in Cold Areas 
• 
When using in cold region with severe cold 
climate and heavy snow, water discharged from 
the heat exchanger will freeze on the base 
surface and this may block the drainage. In such 
regions,  remove the bush on the bottom face of 
outdoor unit to prevent water build up leading to 
icing and blockage. Keep a minimum gap of 
250mm between the base and the ground. When 
using drain pipe, consult your sales agent
DRAIN PIPE 
BASE 
DRAIN PIPE 
BUSH 
BUSH 
1
0
0
mm ABO
V
E