Hitachi RAC-25WPA RAC25WPA ユーザーズマニュアル

製品コード
RAC25WPA
ページ / 706
 
13-10
 
 
 
•  Applicable models :RAK-60PPA 
 
 
– 
Remove the screw and electrical cover 
– 
Insert the connecting cord (A,B, C, D) from the 
bottom of unit 
– 
 Fixed the wire to terminal wires firmly as shown in 
the figure  
 
• 
Applicable models : RAK-70PPA 
 
 
– 
Remove the screw and electrical cover 
– 
Insert the connecting cord (A,B, C, D) from the 
bottom of unit 
– 
 Fixed the wire to terminal wires firmly as shown in 
the figure at right side. 
 
 
• 
Applicable models : 
RAD-50PPA 
RAD-60PPA 
RAD-70PPA 
 
WARNING: 
– 
The appliance must be earthed 
– 
Remove the cover of the electric box. 
– 
Connect the connecting cords 
– 
Assemble the cover of electric box 
 
 
13.3.3 ELECTRICAL WIRING FOR OUTDOOR UNIT 
Please remove the side cover for wire connection 
WARNING: 
– 
If you cannot attach the side cover due to the 
connecting cord, press the connecting cord in direction 
to the front panel to fix it.. 
– 
Be sure that the hooks of the side cover are fixed in 
certainly. Otherwise water leakage may occur and this 
causes short circuit of faults.. 
– 
The connecting cord should not touch the service 
valve or pipes. (It becomes high temperature during 
heating operation) 
Checking for electric source and the voltage range 
• 
Before installation, the power source must be checked 
and the necessary wiring work must be completed. To 
ensure poper wiring capacity, refer to the list of wire 
gauges below for the lead-in from the pole transformer 
and for the wiring from a switch board of a fuse box to 
the main switch and outdoor unit in consideration o 
fthe locked rotor current. 
Connecting 
cords 
After unscrew the band, 
put the connecting cords 
and fix again with screw. 
(2places) 
Connect the earth 
wire (green and 
yellow wire) 
Insert and fix the 
connecting cords 
with screw (4 
places) 



Electrical cover 
Screw 
Connect the 
earth cord 
After remove the screw 
and band, put the 
connecting cords and 
fix the band with screw 
Electrical cover 
Screw 
Connect the 
cord 
After remove the screw 
and band, put the 
conneting cords and fix 
the band with screw. 
Screw