Hitachi RAC-25WPA RAC25WPA ユーザーズマニュアル

製品コード
RAC25WPA
ページ / 706
 
14-4
 
 
14.1.3  MULTIZONE/MONO SPLIT RAM-53NP2A / 53NP3A / 68NP3A / 70NP4A , MONO SPLIT RAF-50PXA/RAC-
50FXA 
Warning 
Remember that voltage of 162V is applied to the 0V line on the 
P.W.B. or the like as shown in the diagram below 
Warning 
When using an oscilloscope, never ground it. Don’t forget that 
high voltage as noted in the left figure may apply to the 
oscilloscope. 
 
 
 
 
14.1.4  MULTIZONE RAM-90NP5A 
Warning 
Remember that the 0V line is biased at 162V in reference to 
the ground level. Also note that it takes about 10 minutes until 
the voltage fall after the power switch is turned OFF. 
Warning 
When using an oscilloscope, never ground it. Don’t forget that 
high voltage as noted in the left figure may apply to the 
oscilloscope. 
 
 
 
Power source 
Smoothing Capacitor 
Control 
P.W.B 
MAIN 
P.W.B 
C  DC35V 
0V 
Compressor 
IPM
 
A
C
T M
odul
e
 
 
 
0V 
Across  (0V line) approx 260~360V 
Across 
–ground approx 155~170V 
Across 
 (0V line)-ground approx 155~170V 
Outdoor unit P.W.B. 
 
Always keep your 
hands and metallic 
things away from the 
enclosure of the 
oscilloscope 
DANGER! 
Don’t install 
the ground 
line 
Power source 
System power module 
MAIN P.W.B. 
Control 
P.W.B. 
Indoor 
 
Compressor 
motor 
DC35V 
0V 
0V 
P
o
w
e
r mo
d
u
le
 
ACT
 
mod
ul
e
 
 
ⓐ 
Across -ⓑ (0V line)        approx 360V 
Across 
–ground              approx 155~170V 
Across 
 (0V line)-ground approx 155~170V 
Outdoor unit 
P.W.B. 
 
Always keep your 
hands and metallic 
things away from 
the enclosure of the 
oscilloscope 
DANGER! 
Don’t install 
the ground 
line