14.3.1  SUPPORT FUNCTION OF FAILURE DIAGNOSIS 
No. 
Function Name 
Description 
Self-diagnosis function  
<indicating a failure on 
the indoor unit> 
• 
The “timer lamp indicates a mode of failure detected on the indoor or outdoor unit side by 
blinking frequency. 
• 
A failure detected on the outdoor unit side will be indicated by the “timer lamp” blinking 4 
times after a retry operation has been performed several times. 
Note: In some failure modes, only the retry operation is repeated without lamp indication. 
<Failure modes that will repeat a retry operation without the indoor unit lamp indication are as 
follow :> 
OH thermistor temperature rise 
Outdoor unit communication error. 
Power voltage abnormal 
Less frequent defects. 
 
<Indicating a failure on 
the outdoor unit> 
• 
The “LD301” indicates a mode of failure detected on the outdoor unit side by the blinking 
frequency. 
Upon failure detection, the outdoor unit will shut down and the LD301 continues to blink 
until the unit is reset. (In the event of communication errors, the LD301 continues to blink 