14.5  CHECKING OUTDOOR UNIT ELECTRICAL PARTS 
14.5.1  NO OPERATION OR ABNORMAL OPERATION (RAC-18/25/35WPA, RAC-18/25/35/50WEA, RAC-
25/35FPA, RAC-25/35FXA 
Is AC220~240V being generated at terminals L-N?
Are the connections for 
terminals C-D correct?
Correct properly. (Be sure to turn the power 
off before correcting the connection
Is the 15A fuse normal?
If the 15A Fuse has 
blown, other parts may 
also be defective
Replace defective parts
Is the power circuit normal? See the 
description on power circuit for details
Check to see if -D cables are connected 
correctly. If reversed or incompletely 
inserted, correct the cable connection.
Is 5V being generated 
between Pin
n⑥ (0V) and Pin
(5V) at CN18(test pin)?
Is the switching power 
circuit OK? Has the 3A 
fuse blown?
Replace defective parts
With the piping and lines (L,N,C,D) connected, operate the unit in 
the forced cooling mode using the outdoor unit service switch.
How did the self-diagnosis 
lamp (LD301) blink?
LD301 blinks 12 times Fan 
lock error.
Is CN24 connected
Connect the connector
Is the propeller fan locked?
Remove any obstructions
Have the 1A fuse and R107 
blown?
Replace the fan 
motor and main PWB
Is +15V being generated? Check both 
between CN18
③ and ⑥ on the main PWB
Is the fan operating? 
(An error occurs after 
the fan operate for 2 
minutes)
Is voltage between and at CN24 normal? 
Check to see if the voltage is within 2.5V±0.5V 
using a tester. (In effect, the output voltage is 
alternatively switched between 5V and 0V)
Replace the fan 
motor
Is the voltage between  ④ and ⑥ at CN24 normal? 
(Normally, the voltage is above approx. DC1.7V)
Replace the main 
PWB
LD301 blinks 10 times. 
Defective power supply voltage.
Is AC220~240V being 
output at terminals A-B.
Apply AC220~240V. Check 
the interior wiring.
TAB05, TAB11, reactor, and C023 
(yellow green) connected properly?
Connect properly
Replace the main PWB. Possible causes 
Power delay malfunction  Defective 
microcomputer
Yes
No
No
Yes
No
Yes
Power is OK
NG (Fuse blown)
Yes
Yes
No
Yes
No
Yes
No
Yes
No
No
Yes
Yes
No
No
Yes
No
Yes
Yes
No
No
Yes
Yes
No