14.7.5  MONO SPLIT INDOOR (RAF-25/35/50PXA) 
No 
Blinking of TIMER lamp 
Reason for indication 
Possible causes 
 
When the indoor heat exchanger 
temperature is too low in the heating 
mode or it is too high in the cooling mode. 
Reversing valve defective 
1times 
1)  Reversing valve defective 
2)  Heat exchanger thermistor 
disconnected (only in heating mode) 
(Note) 
The malfunction mode is displayed only 
after  the abnormal condition occurrs 3
rd
 
time (read every 3 minutes 
 
 
When the outdoor unit is in forced 
operation or balancing operation after 
forced operation 
Outdoor unit is under forced operation. 
Electrical parts in the outdoor unit. 
 
 
When the interface signal from the 
outdoor unit is interrupted. 
Indoor/outdoor interface defective 
1)  Indoor interface circuit. 
2)  Outdoor interface circuit 
 
 
When the error mode is detected times 
within 30 minutes from outdoor unit 
electrical components. (However, when 
error is detected 8 times within two hours 
only for outdoor thermistor 
Outdoor unit electrical components 
defective 
Outdoor unit electrical components. (For 
details, operate again using remote 
controller and check from self-diagnosis 
display of outdoor unit) 
 
 
When room thermistor or heat exchanger 
thermistor is opened circuit or short circuit. 
Room thermistor or heat exchanger 
thermistor is faulty 
1)  Room thermistor 
2)  Heat exhanger thermistor 
 
 
When over-current is detected at the DC 
fan motor of the indoor unit. 
Over-current detection at the DC fan 
motor 
10times 
1)  Indoor fan locked 
2)  Indoor fan  motor 
3)  Indoor control P.W.B. 
 
1)    Connecting Cord Defective 
Interface voltage error 
2)    Outdoor Defective 
 
When data read from IC401 or IC402 is 
incorrect. 
IC401 or IC402 data reading error 
IC401 or IC402 abnormal 
*Note: Refer to Chapter 9 for error codes displayed on remote controllers. 
(
 Lights for 0.35 sec. at interval of 0.35 sec.) 
<Cautions> 
1)  If the interface circuit is faulty when power is supplied, the self diagnosis display will not be displayed 
2)  If the indoor unit does not operate at all, check if the connecting cable is connected to the outdoor unit. 
 
 
2sec 
1 time 
2sec 
2 times 
2sec 
3 times 
2sec 
9 times 
2sec 
10times 
2sec 
12times 
2sec 
13times 
2sec 
4 times