14.8  TROUBLESHOOTING WHEN OUTDOOR LED LAMP BLINKS 
14.8.1  MONOZONE RAC-25NPA / 35NPA / 50NPA  
SELF-DIAGNOSIS LIGHTING MODE 
  : LIGHT 
  : BLINK 
  : OFF 
LD301 
LD302 
SELF DIAGNOSIS NAME 
DETAIL 
MAIN CHECK POINT 
 
1.  DURING OPERATION 
LD303 (RED) LIGHTS.  
 
 
 
Normal operation 
Compressor operation 
Not malfunction 
 
 
Overload (1) 
 
The rotation speed is automatically controlled to 
protect the compressor in the overload 
condition. 
This shows an overload but not malfunction. 
 
 
Overload (2) 
 
 
Overload (3) 
 
2.  DURING STOP 
LD303 (RED) GOES OFF.  
 
 
 
Normal stop 
Stopped by Thermostat or Controller 
NOT MALFUNCTION 
 
 
Reset stop 
Microprocessor was re-booted. (It is 
NORMAL when power SW has been 
turned ON) 
 ①Main P.W.B.  
1 time 
 
 
Peak current cut 
Compressor Peak Current was 
beyond the maximum limit
 
①Main P.W.B. 
②Compressor 
2 times 
 
 
Abnormal low speed rotation 
Compressor Rotor position could not 
be detected. 
①Main P.W.B. 
②Compressor 
3 times 
 
 
Switching failure 
Switching from low frequency sync 
start to position detection operation 
failure 
①Main P.W.B. 
②Compressor 
4 times 
 
 
Overload lower limit cut 
Overload protection mechanism is 
requesting compressor to run at a 
speed lower than the minimum 
speed limit 
①Outdoor unit is exposed to direct sunlight or 
its airflow is blocked. 
②Fan motor              ③Main PWB 
④The Voltage is extremely LOW 
5 times 
 
 
OH thermistor temperature rise 
OH thermistor detected compressor 
overheat 
①Leak of refrigerant. 
②Compressor 
③OH thermistor circuit. 
6 times 
 
 
Thermistor abnormal 
Abnormal thermistor value was 
detected (Open or Short) 
①Thermistor. 
②Connection of thermistor defective. 
③Thermistor circuit. 
7 times 
 
 
Acceleration failure 
Compressor acceleration was not 
more that the minimum speed 
setting. 
①Leak of refrigerant. 
②Compressor. 
8 times 
 
 
Communication error 
Communication between indoor and 
outdoor is interrupted 
①C-D cable wrongly connected 
②Open connection on the C-D cable. 
③Interface circuit of indoor/outdoor unit. 
9 times 
 
 
Abnormal power voltage 
Abnormal power source is detected. 
①Abnormal power source 
②Cable is wrongly connected 
③Main P.W.B. 
10 times 
 
 
Fan lock error 
Outdoor fan actual rpm could not 
reach as per instructed. 
①Outdoor fan motor 
②Fan motor circuit. 
12 times 
 
 
EEPROM read error 
Microcomputer cannot read the data 
in EEPROM. 
①Main P.W.B.  
13 times 
 
 
ACTIVE CONVERTER 
defective 
Over Voltage is detected by System 
Power Module 
①System Power Module.  
14 times 
Example of blinking (5 times) 
 
2SEC 
Lights for 0.25 sec at 
interval of 0.25 sec 
 
TIME 
SET 
VALUE 
RO
T
AT
IO
SPEED
 
(1) 
(2) 
(3)