Hitachi RAF-35RPA RAF35RPA ユーザーズマニュアル
製品コード
RAF35RPA
CAPACITIES AND SELECTION DATA
4-301
4.6.4. RAM-53NP3A
Whichever indoor units are installed, cooling and heating capacity depends on how many and which indoor units are operating at
the same time.
POSSIBLE
COMBINATIONS
TO OPERATE
COOLING
HEATING
TOTAL
(kW)
CAPACITY
RATING
(kW)
RANGE)
OUTDOOR UNIT
EER Class
CAPACITY
RATING
(kW)
(RANGE)
OUTDOOR UNIT
COP
Class
TOTAL
INPUT
(W)
AMPERE(A)
TOTAL
INPUT
(W)
AMPERE(A)
TOTAL
220V 230V 240V
TOTAL
220V 230V 240V
ONE
UN
IT
1.2
1.2
1.20
1.20
370
1.7 1.6 1.6 3.24
A
1.80
1.80
495
2.3 2.2 2.1 3.64
A
(1.00-1.60)
(200-480)
(1.10-2.20)
(200-650)
1.8
1.8
1.80
1.80
495
2.3 2.2 2.1 3.64
A
2.50
2.50
690
3.2 3.0 2.9 3.62
A
(1.00-2.00)
(200-750)
(1.10-3.20)
(200-1050)
2.5
2.5
2.50
2.50
700
3.2 3.1 2.9 3.57
A
3.90
3.90
1060
4.9 4.7 4.5 3.68
A
(1.00-2.80)
(200-980)
(1.10-4.70)
(200-1380)
3.5
3.5
3.50
3.50
1030
4.7 4.5 4.3 3.40
A
4.80
4.80
1320
6.1 5.8 5.6 3.64
A
(1.00-3.90)
(200-1280)
(1.10-5.80)
(200-1870)
5.0
5.0
5.00
5.00
1510
6.9 6.6 6.4 3.31
A
6.50
6.50
1800
8.3 7.9 7.6 3.61
A
(1.00-5.50)
(200-1660)
(1.10-7.20)
(200-2010)
T
W
O
U
NIT
S
1.2+1.2
2.4
1.20+1.20
2.40
690
3.2 3.0 2.9 3.48
A
1.80+1.80
3.60
950
4.4 4.2 4.0 3.79
A
(1.50+2.80)
(200-980)
(1.50-4.20)
(200-1100)
1.2+1.8
3.0
1.20+1.80
3.00
920
4.2 4.0 3.9 3.26
A
1.80+2.50
4.30
1100
5.1 4.8 4.6 3.91
A
(1.50-3.50)
(200-1000)
(1.50-5.20)
(200-1300)
1.2+2.5
3.7
1.20+2.50
3.70
1030
4.7 4.5 4.3 3.59
A
1.80+3.90
5.70
1450
6.7 6.4 6.1 3.93
A
(1.50-4.00)
(200-1300)
(1.50-6.40)
(200-1780)
1.2+3.5
4.7
1.20+3.50
4.70
1390
6.4 6.1 5.9 3.38
A
1.80-4.80
6.60
1660
7.6 7.3 7.0 3.98
A
(1.50-5.20)
(200-1450)
(1.50-7.20)
(200-2010)
1.2+5.0
6.2
1.03+4.27
5.30
1528
7.0 6.7 6.4 3.47
A
1.47+5.33
6.80
1790
8.2 7.9 7.5 3.80
A
(1.50-5.90)
(200-1660)
(1.50-7.20)
(200-2010)
1.8+1.8
3.6
1.80+1.80
3.60
1015
4.7 4.5 4.3 3.55
A
2.50+2.50
5.00
1290
5.9 5.7 5.4 3.88
A
(1.50-4.00)
(200-1300)
(1.50-5.20)
(200-1550)
1.8+2.5
4.3
1.80+2.50
4.30
1167
5.4 5.1 4.9 3.68
A
2.50+3.90
6.40
1700
7.8 7.5 7.2 3.76
A
(1.50-4.60)
(200-1450)
(1.50-6.30)
(200-1920)
1.8+3.5
5.3
1.80+3.50
5.30
1500
6.9 6.6 6.3 3.53
A
2.31+4.49
6.80
1850
8.5 8.1 7.8 3.68
A
(1.50-5.60)
(200-1660)
(1.50-7.20)
(200-2010)
1.8+5.0
6.8
1.40+3.90
5.30
1528
7.0 6.7 6.4 3.47
A
1.80+5.00
6.80
1820
8.4 8.0 7.7 3.74
A
(1.50-5.90)
(200-1660)
(1.50-7.20)
(200-2010)
2.5+2.5
5.0
2.50+2.50
5.00
1472
6.8 6.5 6.2 3.40
A
3.40+3.40
6.80
1885
8.7 8.3 7.9 3.61
A
(1.50-5.60)
(200-1660)
(1.50-7.20)
(200-2010)
2.5+3.5
6.0
2.21+3.09
5.30
1528
7.0 6.7 6.4 3.47
A
2.83+3.97
6.80
1820
8.4 8.0 7.7 3.74
A
(1.50-5.70)
(200-1660)
(1.50-7.20)
(200-2010)
3.5+3.5
7.0
2.65+2.65
5.30
1528
7.0 6.7 6.4 3.47
A
3.40+3.40
6.80
1790
8.2 7.9 7.5 3.80
A
(1.50-5.90)
(200-1660)
(1.50-7.20)
(200-2010)
2.5+5.0
7.5
1.77+3.53
5.30
1528
7.0 6.7 6.4 3.47
A
2.27+4.53
6.80
1790
8.2 7.9 7.5 3.80
A
(1.50-5.90)
(200-1660)
(1.50-7.20)
(200-2010)
3.5+5.0
8.5
2.18+3.12
5.30
1528
7.0 6.7 6.4 3.47
A
2.80+4.00
6.80
1790
8.2 7.9 7.5 3.80
A
(1.50-6.60)
(200-1660)
(1.50-7.20)
(200-2010)