Tycon Systems UPS-ST24-100-8-UBNT データシート
Outdoor UPS System
Features
192W Maximum Continuous Output
7 Switched 24VDC POE Ports, 1 Data Uplink Port
Designed Specifically for Ubiquiti and Mikrotik Applications
Isolates Equipment from Power Line Surges
High Performance GEL Sealed Lead Acid Batteries
Choice of 51Ah (1200VA) or 102Ah (2400VA)
Weatherproof Nema 4X / IP65, UV Resistant, Locking Outdoor
Enclosure
Applications
Description
The UPS
Pro™ UBNT outdoor UPS system is designed specifically for 24VDC POE equipment like that from Ubiquiti,
Mikrotik, Tranzeo, etc. The system provides up to 192W of continuous regulated 24VDC power on 7 switched power
over Ethernet (POE) ports. There is also a data uplink port if an external data connection is desired. The system is
powered from 120/240VAC grid power.
over Ethernet (POE) ports. There is also a data uplink port if an external data connection is desired. The system is
powered from 120/240VAC grid power.
The proprietary charge controller maintains the proper charge on the
batteries to prevent over charge and controls the load to prevent over-
discharge.
batteries to prevent over charge and controls the load to prevent over-
discharge.
The weatherproof enclosure with security locks has multiple ports for CAT5
cable, solar and other cabling. It is vented to prevent residual buildup of any
hydrogen gas. The included bracket kit allows for the enclosure to be pole
mounted or wall mounted. The systems are rated to operate over a wide
temperature range of -30C to +60C.
cable, solar and other cabling. It is vented to prevent residual buildup of any
hydrogen gas. The included bracket kit allows for the enclosure to be pole
mounted or wall mounted. The systems are rated to operate over a wide
temperature range of -30C to +60C.
There are 3 system configurations available: 51Ah Battery capacity, 102Ah
battery capacity and also a system without batteries for those customers who
want to use their own sealed lead acid type batteries. Battery life on the high
performance GEL cells is rated at 5 years. Typical recharge time from a full
discharge is just a few hours.
battery capacity and also a system without batteries for those customers who
want to use their own sealed lead acid type batteries. Battery life on the high
performance GEL cells is rated at 5 years. Typical recharge time from a full
discharge is just a few hours.
There is a generous amount of space reserved inside the enclosures for
customer electronics such as controllers, wireless AP or CPE cards, sensors,
inverters, etc. The standard component layout is designed for ease of maintenance.
customer electronics such as controllers, wireless AP or CPE cards, sensors,
inverters, etc. The standard component layout is designed for ease of maintenance.
Equipment runs on battery power to isolate it from power line surges which is a main
cause of outdoor equipment failure.
cause of outdoor equipment failure.
Ubiquiti Base Stations
Security Applications
Mikrotik Base Stations
24VDC POE Equipment