Intel SR1640TH SR1640THNA ユーザーズマニュアル

製品コード
SR1640THNA
ページ / 122
Functional Architecture 
Intel® Server System SR1640TH TPS 
  
Revision 
1.0 
Intel order number: E94847-001 
40 
 
Main 
Advanced 
Security 
Server Management 
Boot Options 
Boot Manager 
 
 
Assert NMI on SERR 
Enabled / Disabled 
Assert NMI on PERR 
Enabled / Disabled 
Resume on AC Power Loss 
Stay Off / Last state / Reset 
Clear System Event Log 
Enabled / Disabled 
 
FRB-2 Enable 
Enabled / Disabled 
 
O/S Boot Watchdog Timer  
Enabled / Disabled 
O/S Boot Watchdog Timer Policy 
Power off / Reset 
O/S Boot Watchdog Timer Timeout 
5 minutes / 10 minutes / 15 minutes / 20 minutes 
 
 
Plug & Play BMC Detection 
Enabled / Disabled 
 
 
► System Information 
► BMC Configuration 
 
 
 
 
Figure 18. Setup Utility – Server Management Configuraiton Screen Display 
Table 22. Setup Utility – Server Management Configuration Screen Fields 
Setup Item 
Options 
Help Text 
Comments 
Assert NMI on SERR 
Enabled 
Disabled 
On SERR, generate an NMI and log an error. 
Note: [Enabled] must be selected for the Assert NMI 
on PERR setup option to be visible. 
 
Assert NMI on PERR 
Enabled 
Disabled 
On PERR, generate an NMI and log an error. 
Note: This option is only active if the Assert NMI on 
SERR option is [Enabled] selected. 
 
Resume on AC 
Power Loss 
Stay Off 
Last state 
Reset 
System action to take on AC power loss recovery. 
[Stay Off] - System stays off. 
[Last State] - System returns to the same state before 
the AC power loss. 
[Reset] - System powers on. 
 
Clear System Event 
Log 
Enabled 
Disabled 
If enabled, clears the System Event Log. All current 
entries will be lost. 
Note: This option is reset to [Disabled] after a reboot. 
 
FRB-2 Enable 
Enabled 
Disabled 
Fault Resilient Boot (FRB). 
If enabled, the BIOS programs the BMC watchdog 
timer for approximately 6 minutes. If the BIOS does 
not complete POST before the timer expires, the BMC 
resets the system. 
 
O/S Boot Watchdog 
Timer 
Enabled 
Disabled 
If enabled, the BIOS programs the watchdog timer 
with the timeout value selected. If the OS does not 
complete booting before the timer expires, the BMC 
resets the system and an error is logged. 
Requires OS support or Intel Management Software. 
 
O/S Boot Watchdog 
Timer Policy 
Power Off 
Reset 
If the OS boot watchdog timer is enabled, this is the 
system action taken if the watchdog timer expires. 
[Reset] - System performs a reset. 
[Power Off] - System powers off. 
Grayed out when the O/S 
Boot Watchdog Timer is 
disabled. 
O/S Boot Watchdog 
Timer Timeout 
5 minutes 
10 minutes 
15 minutes 
20 minutes 
If the OS watchdog timer is enabled, this is the 
timeout value used by the BIOS to configure the 
watchdog timer. 
Grayed out when the O/S 
Boot Watchdog Timer is 
disabled.