Conrad Energy Alkaline AAA Battery x24 pc(s) 650638 データシート
製品コード
650638
PRODUCT SPECIFICATION
Product
Alkaline battery, 1.5 volts
Page
3 of 5
Size LR03,
Micro,
AAA
Conrad Electronic SE, Klaus-Conrad-Straße 1, 92240 Hirschau, Germany
Tel. 0180/5312111, Fax 0180/5312110, webmaster@conrad.de, www.conrad-energy.de, www.conrad.de
14.
Safety test (Test environment: 20
℃±2,60%±15%R.H)
Test item
Test method
Test pcs
Requirements
20ohms (24h/d) 48hours
9pcs
No leakage
5.1ohms (4min/h,8h/d) to 0.6V
9pcs
No leakage
600mA (10s/min, 1h/d) to 0.6V
9pcs
No leakage
10ohms (1h/d) to 0.6V
9pcs
No leakage
75ohms (4h/d) to 0.6V
9pcs
No leakage
Over-discharge
leakage test
24ohms (15s/mn, 8h/d) to 0.6V
9pcs
No leakage
High temperature
test
60
±2℃,RH:90±5%, after 20 days storage, the cells
shall be stored in an ambient temperature of
20
±2℃,RH:60±5%, for 4-24hours.
40 No
leakage
One piece of battery
Short circuit test
The terminal of an un-discharged battery is connected by wire.
The circuit is completely for 24hours or until the case
temperature has return to environment.
The circuit is completely for 24hours or until the case
temperature has return to environment.
10
No leakage
No explosion
No explosion
Reversible charge
4 pieces of battery are in series connected and one of them is
under incorrect polarity for 24 hours or until the case
temperature has return to environment..
under incorrect polarity for 24 hours or until the case
temperature has return to environment..
40 No
explosion
Over discharge
One battery discharge 75ohms to 0.6V, then in series connect
with 3 pieces of new battery with 20ohm 24h
with 3 pieces of new battery with 20ohm 24h
36 No
explosion
Four pieces of
battery in series
Short circuit test
The terminal of four pieces of battery is connected by wire.
The circuit is completely for 24hours or until the case
temperature has return to environment.
The circuit is completely for 24hours or until the case
temperature has return to environment.
40 No
explosion
Free fall test
The battery free drops from one-meter height for 6 times, then
store for 1h
store for 1h
10 No
explosion
Impact under high
and low temperature
Un-discharged battery store in test box under 70
±2℃
for
24h,then change to -20
℃ for 24h, repeat the above condition
for 10 cycles.
20 No
explosion
Storage after partial
discharge
50% discharged battery stored under 45
±5℃
for 30days
9
No leakage
No explosion
No explosion
15. Expiry
period:
7 years
16.
Expiry period marking:
Expiry date marked on the bottom plate of finished battery . For example: 2015-08 means the Expiry date is
August 2015.
August 2015.