Ebro EBI 300 USB Temperature Datalogger for Food Products 1340-6330 データシート

製品コード
1340-6330
ページ / 52
 
BA80004DEF
 
35 
English 
Français 
Connecting the probe 
If the logger was programmed on using 
an  external  sensor,  but  there  is  no 
probe  connected,  the  device  will 
display 
“NC” (not connected). 
Connect the external probe to the USB-
plug  of  the  logger.  As  soon  as  the 
external  sensor  is  connected,  the 
logger 
displays 
the 
current 
temperature. 
If  you  are  using  the  probe  type  TPX 
250 
for 
deep-temperature-
applications  (<  -30°C),  the  sample 
rate  should  at  least  be  set  to  1 
minute,  in  order  to  increase  the 
battery  life  time.  After  measuring  at 
temperatures  below  -30°C,  it  may 
take  up  to  one  minute  until  the 
logger can be read out. 
 
EBI  300  can  be  used  only  with  the 
external  probe  TPC  300.  If  there  is a 
different 
probe 
connected, 
the 
display 
shows 
NA 
(not 
applicable).and  no  data  will  be 
recorded. 
 
Raccorder une sonde 
Lorsque l'enregistreur a été programmé 
pour l'utilisation d'une sonde externe et 
qu'aucune  sonde  n'est  connectée,  le 
message  NC  (non  connecté)  s'affiche 
sur l'écran. 
Connectez  la  sonde  externe  au  port 
USB  de  l'enregistreur.  Dès  lors  qu'une 
sonde  est  connectée,  l'écran  affiche  la 
température en cours. 
Lorsqu'une  sonde  externe  de  type 
TPX  250  est  utilisée  pour  des 
applications 
à 
très 
basse 
température 
(<-30°C), 
il 
est 
recommandé  de  régler  la  fréquence 
de mesure sur une minute au moins 
pour  optimiser  la  durée  de  vie  des 
batteries.  Après  une  mesure  à  une 
température  <  -30°C,  il  faut  parfois 
patienter  jusqu'à  une  minute  avant 
de pouvoir lire l'enregistreur. 
 
Seul  le  capteur  TPC  300  peut 
fonctionner  avec  l'enregistreur  EBI 
300.  Si  un  autre  capteur  est 
connecté,  l'afficheur  indiquera  NA 
(non  adapté)  et  aucune  valeur  ne 
s'affichera à l'écran.