Lascar Electronics EL-USB-2 Humidity, Temperature and Dew Point USB Data Logger EL-USB-2 データシート

製品コード
EL-USB-2
ページ / 4
This standalone data logger measures and stores up to 16,382 relativehumidity and 16,382 temperature readings over 0 to 100%RH and -35 
to +80°C (-31 to +176°F) measurement ranges. The user can easily set up the logging rate and start-time, 
and download the stored data by plugging the data logger into a PC’s USB port and running the purpose designed software under Windows 
2000, XP and Vista (32-bit). Relative humidity, temperature and dew point (the temperature at which water vapor present in the air begins to 
condense) data can then be graphed, printed and exported to other applications. The data logger is supplied complete with a long-life 
lithium battery, which can typically allow logging for a year. Status indication is via flashing red and green LEDs. The logger is protected 
against ingress from water and dust to IP67 standard when the plastic cap and seal are fitted.
EL-USB-2          
Humidity, Temperature and 
Dew Point USB Data Logger
Specifications liable to change without prior warning   
       Issue 10 
     07/2012                S.L                  Applies to EL-USB-2                   Page 1 of 4
FEATURES
• 0 to 100%RH measurement range
• -35 to +80°C (-31 to +176°F) measurement range
• Dew point indication via Windows control software
• USB interface for set-up and data download
• User-programmable alarm thresholds for %RH & T
• Status indication via red and green LEDs
• Supplied with replaceable internal lithium battery
    and Windows control software
• Environmental protection to IP67
ORDERING INFORMATION
Standard Data Logger
(Data Logger, Software on 
CD, Battery)
Replacement Battery   
EL-USB-2 
BAT 3V6 1/2AA          
www.lascarelectronics.com 
    
* This specifies the overall error in the logged readings, for relative humidity measurements between 20 and 80%RH. 
** This specifies the overall error in the calculated dew point, for relative humidity measurements between 40 and 100%RH at 25°C.
*** Depending on sample rate, ambient temperature and use of alarm LEDs.
 
Specifications
Minimum
Typical
Maximum
Unit
Relative Humidity
Measurement range
0
100
%RH
Repeatability (short term)
±0.1
%RH
Accuracy (overall error)
±3.0*
±5.0
%RH
Internal resolution
0.5
%RH
Long term stability
0.5
%RH/yr
Temperature
Measurement range
-35 (-31)
+80 (+176)
°C (°F)
Repeatability
±0.1 (±0.2)
°C (°F)
Accuracy (overall error)
±0.5 (±1)
±2 (±4)
°C (°F)
Internal resolution
0.5 (1)
°C (°F)
Dew Point
Accuracy (overall error)
±1.1 (±2)**
°C (°F)
Logging rate
every 10s
every 12hr
-
Operating temperature range
-35 (-31)
+80 (+176)
°C (°F)
1/2AA 3.6V Lithium Battery Life
1***
Year