13. tEChNICaL Data
Voltage supply ............................................. 9V-block battery (type 6F22, 1604 or same build)
Reaction time ............................................... 150 ms
Spectrum ..................................................... 8 - 14 µm
Emission degree .......................................... 0.1 to 1.00 can be set
Measuring range IR measurement .............. -50 to +1200 °C (-58 to +2192 °F)
Measuring range contact measurement ...... -50 to +1370 °C (-58 to +2498 °F)
Resolution .................................................... 0.1 °C/°F < 1000 °C/°F
 
1 °C/°F >/= 1000 °C/°F
IR lens (D:S) ................................................ 50:1
Laser ............................................................ Output < 1 mW, laser class 2,
 
Wavelength 630 - 670 nm
Operating temperature ................................ 0 to +50 °C (+32 to 122 °F)
Operating humidity ...................................... 10 - 90% relative humidity
Storage temperature .................................... -10 to +60 °C (+14 to +140 °F)
Storage humidity .......................................... 10 - 80% relative humidity
Weight ......................................................... Approx. 330 g
Dimensions .................................................. 220 x 52 x 138 mm
a) measuring tolerances
The accuracy is valid for one year at a temperature of +23 to +25 °C (+73 to +77 °F), and at a relative humidity of 
less than 75 %, non-condensing.
Infrared temperature measuring area
Measuring area °C
Accuracy
Reproducibility
-50 to +20 °C
±5 °C
±1.5 °C
+20 to +500 °C
±1.5% or
±2 °C
±0.5% or
±0.5 °C
+500 to +1000 °C
±2,5 %
±0.5% or
±0.5 °C
+1000 to +1200 °C
±3,0 %
±1,0 %