external: Performs external loop test. In the external loop test, self-loop 
headers must be used on the port of the switch ( for 100M port, the self-loop 
headers are made from four cores of the 8-core cables, for 1000M port, the 
self-loop header are made from eight cores of the 8-core cables, then the 
packets forwarded by the port will be received by itself.). The external loop test 
can locate the hardware failures on the port.
internal: Performs internal loop test. In the internal loop test, self loop is 
established in the switching chip to locate the chip failure which is related to 
the port.
Note that:
After you use the shutdown command on a port, the port cannot run 
loopback test.
You cannot use the speedduplexmdi and shutdown commands on the 
ports running loopback test.
Some ports do not support loopback test, and corresponding prompts will be 
given when you perform loopback test on them.
Enabling the System to 
Test a Connected Cable
You can enable the system to test the cable connected to a specific port. The test 
result will be returned in five seconds. The system can test these attributes of the 
cable: Receive and transmit directions (RX and TX), short circuit/open circuit or not, 
the length of the faulty cable.
n
Currently, the device is only capable of testing the cable status and cable 
length. For the testing items that are currently not supported, "-" is displayed in 
the corresponding fields of the virtual-cable-test command. 
Cable test cannot be performed on an optical port.
Configuring the 
Interval to Perform 
Statistical Analysis on 
Port Traffic
By performing the following configuration, you can set the interval to perform 
statistical analysis on the traffic of a port.
When you use the display interface interface-type interface-number command 
to display the information of a port, the system performs statistical analysis on the 
traffic flow passing through the port during the specified interval and displays the 
average rates in the interval. For example, if you set this interval to 100 seconds, 
the displayed information is as follows:
 Last 100 seconds input:  0 packets/sec 0 bytes/sec
 
 Last 100 seconds output:  0 packets/sec 0 bytes/sec 
Table 66   Enable the system to test connected cables
Operation 
Command 
Remarks 
Enter system view 
system-view 
Enter Ethernet port view 
interface interface-type 
interface-number
 
Enable the system to test 
connected cables 
virtual-cable-test 
Required