Basic 802.1x Configuration
225
from them in handshaking periods. To prevent users being falsely considered 
offline, you need to disable the online user handshaking function in this case.
For the handshaking packet secure function to take effect, the clients that 
enable the function need to cooperate with the authentication server. If either 
the clients or the authentication server does not support the function, disabling 
the handshaking packet secure function is needed. 
Timer and Maximum 
User Number 
Configuration
As for the dot1x max-user command, if you execute it in system view without 
specifying the interface-list argument, the command applies to all ports. You 
can also use this command in port view. In this case, this command applies to 
the current port only and the interface-list argument is not needed.
Table 163   Configure 802.1x timers and the maximum number of users
Operation
Command 
Remarks 
Enter system view
system-view 
Set the 
maximum 
number of 
concurren
t on-line 
users for 
specified 
ports 
In system 
view 
dot1x max-user user-number [ 
interface interface-list ] 
Optional
By default, a port can 
accommodate up to 256 users at 
a time. 
In port 
view 
interface interface-type 
interface-number
dot1x max-user user-number
quit
Set the maximum retry 
times to send request 
packets
dot1x retry max-retry-value 
Optional
By default, the maximum retry 
times to send a request packet is 
2. That is, the authenticator 
system sends a request packet to 
a supplicant system for up to two 
times by default. 
Set 802.1x timers
dot1x timer { 
handshake-period 
handshake-period-value | 
quiet-period quiet-period-value 
server-timeout 
server-timeout-value | 
supp-timeout 
supp-timeout-value | tx-period 
tx-period-value | ver-period 
ver-period-value } 
Optional
The settings of 802.1x timers are 
as follows.
handshake-period-value: 
15 seconds
quiet-period-value: 60 
seconds
server-timeout-value: 100 
seconds
supp-timeout-value: 30 
seconds
tx-period-value: 30 
seconds
ver-period-value: 30 
seconds 
Enable the 
quiet-period timer
dot1x quiet-period 
Optional
By default, the quiet-period timer 
is disabled.