PoE Configuration
343
After the PoE feature is enabled, perform the following configuration to enable 
the PD compatibility detection function.
Configuring a PD 
Disconnection Detection 
Mode
To detect the PD connection with PSE, PoE provides two detection modes: AC 
detection and DC detection. The AC detection mode is energy saving relative to 
the DC detection mode.
c
Caution: If you adjust the PD disconnection detection mode when the device is 
running, the connected PDs will be powered off. Therefore, be cautious when 
doing so.
Configuring PoE 
Over-Temperature 
Protection on the Switch
If this function is enabled, the switch disables the PoE feature on all ports when its 
internal temperature exceeds 65
°C (149°F) for self-protection, and restores the 
PoE feature settings on all its ports when the temperature drops below 60
°C 
(140
°F).
When the internal temperature of the switch decreases from X (X>65
°
C, or 
X>149
°
F) to Y (60
°
C
Y<65
°
C, or 140
°
F
Y<149
°
F), the switch still keeps the 
PoE function disabled on all the ports.
When the internal temperature of the switch increases from X (X<60
°
C, or 
X<140
°
F) to Y (60
°
C<Y
65
°
C, or 140
°
F <Y
149
°
F), the switch still keeps the 
PoE function enabled on all the ports.
Upgrading the PSE 
Processing Software 
Online
The online upgrading of PSE processing software can update the processing 
software or repair the software if it is damaged. Before performing the following 
configuration, download the PSE processing software to the Flash of the switch.
Table 265   Configure the PD compatibility detection function
Operation 
Command 
Description 
Enter system view 
system-view 
Enable the PD compatibility 
detection function 
poe legacy enable 
Required
Disabled by default.
Table 266   Configure a PD disconnection detection mode
Operation
Command
Description
Enter system view
system-view
-
Configure a PD disconnection 
detection mode
poe disconnect { ac | dc }
Optional
The default PD disconnection 
detection mode is AC.
Table 267   Configure PoE over-temperature protection on the switch
Operation 
Command 
Description 
Enter system view 
system-view 
Enable PoE over-temperature 
protection on the switch 
poe 
temperature-protection 
enable
 
Optional
Enabled by default.