Information Center Configuration
457
If the system information is output before you input any information following 
the current command line prompt, the system does not echo any command 
line prompt after the system information output.
In the interaction mode, you are prompted for some information input. If the 
input is interrupted by system output, no system prompt (except the Y/N string) 
will be echoed after the output, but your input will be displayed in a new line.
Displaying the Time 
Stamp with the UTC 
Time Zone
To add UTC time zone to the time stamp in the information center output 
information, you must:
Set the local time zone
Set the time stamp format in the output direction of the information center to 
date
Configure to add the UTC time zone to the output information
Setting to Output 
System Information to 
the Console
Setting to output system information to the console
Table 342   Configure synchronous information output
Operation 
Command 
Description 
Enter system view 
system-view 
Enable synchronous 
information output 
info-center synchronous 
Required
Disabled by default
Table 343   Configure to display time stamp with the UTC time zone
Operation
Command
Description
Set the time zone for the 
system
clock timezone zone-name { 
add | minus } time
Required
By default, UTC time zone is 
set for the system.
Enter system view
system-view
-
Set the time 
stamp format 
in the output 
direction of 
the 
information 
center to date
Log host 
direction
info-center timestamp 
loghost date
Required
Use either command
Non log 
host 
direction
info-center timestamp { log | 
trap | debugging } date
Set to display the UTC 
time zone in the output 
information of the 
information center
info-center timestamp utc
Required
By default, no UTC time zone 
is displayed in the output 
information
Table 344   Set to output system information to the console
Operation 
Command 
Description 
Enter system view 
system-view 
Enable the information center  info-center enable 
Optional
Enabled by default.