Trade name: Powergel-2 Komponente Komp.A 
Product no.: F1 
Current version : 2.1.1, issued: 20.11.2013  
Replaced version: 2.1.0, issued: 09.01.2013 
Region: GB 
 
 
 
 
 
 
Page 3 of 8 
SECTION 7: Handling and storage 
7.1 
Precautions for safe handling 
Advice on safe handling 
Open and handle container with care. Ensure adequate ventilation. Keep container tightly closed. 
General protective and hygiene measures 
Observe the usual precautions when handling chemicals. Do not eat or drink during work - no smoking. Wash hands 
before breaks and after work. Ensure sufficient room ventilation. 
Advice on protection against fire and explosion 
Product may split off hydrogen. May form explosive mixtures in partially empty containers. Keep away from sources of 
ignition - refrain from smoking. Take precautionary measures against static charges. 
7.2 
Conditions for safe storage, including any incompatibilities 
Technical measures and storage conditions 
Keep containers dry and cool. 
Requirements for storage rooms and vessels 
Keep in original packaging, tightly closed. 
Advice on storage assembly 
Do not store together with: Alkalis; Amines; Ammonia; Alcohols; Oxidizing agents; Acids; Protect against humidity 
7.3 
Specific end use(s) 
No data available. 
  
SECTION 8: Exposure controls/personal protection 
8.1 
Control parameters 
No parameters available for monitoring. 
8.2 
Exposure controls 
Appropriate engineering controls 
Provide good ventilation. 
Personal protective equipment 
Respiratory protection 
No special measures required. 
Eye / face protection 
Safety glasses recommended 
Hand protection 
Sufficient protection is given wearing suitable protective gloves checked according to i.e. EN 374, in the event of risk 
of skin contact with the product . Before use, the protective gloves should be tested in any case for its specific work-
station suitability (i.e. mechanical resistance, product compatibility and antistatic properties). Adhere to the 
manufacturer
’s instructions and information relating to the use, storage, care and replacement of protective gloves. 
Protective gloves shall be replaced immediately when physically damaged or worn. Design operations thus to avoid 
permanent use of protective gloves. 
Appropriate Material 
butyl rubber 
Appropriate Material 
neoprene 
Appropriate Material 
PVC 
Other 
Wear suitable protective clothing 
Environmental exposure controls 
No data available.