Omron G2R-2-SNI 24 VAC PCB Mount Relay 24Vac 2 CO, DPDT G2R-2-SNI 24 VAC データシート

製品コード
G2R-2-SNI 24 VAC
ページ / 29
4
G2R
G2R
Double-winding Latching Relays
Note:
1. The rated current and coil resistance are measured at a coil temperature of 23
°
C with a tolerance of 
±
10%.
2. Operating characteristics are measured at a coil temperature of 23
°
C.
Contact Ratings
PCB/Flux Protection, Plug-in, Quick-connect Terminal Relays
Note:
1. P level: 
l
60
 = 0.1 x 10
–6
/operation
2. ( ): Bifurcated crossbar contact type.
PCB/Flux Protection Relays
Note:
P level: 
l
60
 = 0.1 x 10
–6
/operation
Rated voltage
5 VDC
6 VDC
12 VDC
24 VDC
Set coil
Rated current (see note 1.)
167 mA
138 mA
70.6 mA
34.6 mA
Coil resistance (see note 1.)
30 
W
43.5 
W
170 
W
694 
W
Coil inductance
(H) (ref. value)
Armature OFF
0.073
0.104
0.42
1.74
Armature ON
0.146
0.208
0.83
3.43
Reset coil
Rated current
119 mA
100 mA
50 mA
25 mA
Coil resistance
42 
W
60 
W
240 
W
960 
W
Coil inductance
(H) (ref. value)
Armature OFF
0.003
0.005
0.018
0.079
Armature ON
0.006
0.009
0.036
0.148
Must set voltage
70% max. of rated voltage
Must reset voltage
70% max. of rated voltage
Max. voltage
140% of rated voltage (at 23
•
C)
Power consumption
Set coil: Approx. 850 mW; Reset coil: Approx. 600 mW
Item
General-purpose, quick-connect terminal
High-capacity
Number of poles
1 pole
2 poles
1 pole
Load
Resistive load
(cos
f
 = 1)
Inductive load
(cos
f
 = 0.4; 
L/R = 7 ms)
Resistive load
(cos
f
 = 1)
Inductive load
(cos
f
 = 0.4; 
L/R = 7 ms)
Resistive load
(cos
f
 = 1)
Inductive load
(cos
f
 = 0.4; 
L/R = 7 ms)
Rated load
10 (1) A at 250 VAC;
10 (1) A at 30 VDC
7.5 A at 250 
VAC;
5 A at 30 VDC
5 A at 250 
VAC;
5 A at 30 VDC
2 A at 250 VAC; 
3 A at 30 VDC
16 A at 250 
VAC;
16 A at 30 VDC
8 A at 250 VAC; 
8 A at 30 VDC
Rated carry current
10 (1) A
5 A
16 A
Max. switching voltage 380 VAC, 125 VDC
380 VAC, 125 VDC
380 VAC, 125 VDC
Max. switching current 10 (1) A
5 A
16 A
Max. switching power
2,500 (250) VA,
300 (30) W
1,875 VA, 
150 W
1,250 VA, 
150 W
500 VA, 
90 W
4,000 VA, 
480 W
2,000 VA, 
240 W
Failure rate 
(reference value)
100 mA at 5 VDC (1 mA at 5 VDC)
10 mA at 5 VDC
100 mA at 5 VDC
Item
Bifurcated contacts
High-sensitivity
Number of poles
1 pole
1 pole
2 poles
Load
Resistive load
(cos
f
 = 1)
Inductive load
(cos
f
 = 0.4; 
L/R = 7 ms)
Resistive load
(cos
f
 = 1)
Inductive load
(cos
f
 = 0.4; 
L/R = 7 ms)
Resistive load
(cos
f
 = 1)
Inductive load
(cos
f
 = 0.4; 
L/R = 7 ms)
Rated load
5 A at 250 VAC;
5 A at 30 VDC
2 A at 250 VAC; 
3 A at 30 VDC
5 A at 250 VAC;
5 A at 30 VDC
2 A at 250 VAC; 
3 A at 30 VDC
3 A at 250 VAC;
3 A at 30 VDC
1 A at 250 VAC; 
1.5 A at 30 VDC
Rated carry current
5 A
5 A
3 A
Max. switching voltage 380 VAC, 125 VDC
380 VAC, 125 VDC
380 VAC, 125 VDC
Max. switching current 5 A
5 A
3 A
Max. switching power
1,250 VA, 
150 W
500 VA, 
90 W
1,250 VA, 
150 W
500 VA, 
90 W
750 VA, 
90 W
250 VA, 
45 W
Failure rate 
(reference value)
1 mA at 5 VDC
100 mA at 5 VDC
10 mA at 5 VDC