Omron G6AK-274P-ST-US 12 VDC PCB Mount Signal Relay 12Vdc 2 CO, DPDT G6AK274PSTUS12DC データシート

製品コード
G6AK274PSTUS12DC
ページ / 9
117
G6A
G6A
Precautions
Long-term Continuously ON Contacts
Using the Relay in a circuit where the Relay will be ON continu-
ously for long periods (without switching) can lead to unstable 
contacts because the heat generated by the coil itself will affect 
the insulation, causing a film to develop on the contact surfaces. 
We recommend using a latching relay (magnetic-holding relay) in 
this kind of circuit. If a single-side stable model must be used in 
this kind of circuit, we recommend using a fail-safe circuit design 
that provides protection against contact failure or coil burnout.
Relay Handling
When washing the product after soldering the Relay to a PCB, 
use a water-based solvent or alcohol-based solvent, and keep the 
solvent temperature to less than 40°C. Do not put the Relay in a 
cold cleaning bath immediately after soldering.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. K020-E1-08