G2R
PCB Power Relay
G
2
R
Precautions
Please refer to “PCB Relays Common Precautions” for correct use.
Mounting
• When mounting a number of relays on 
a PCB, be sure to provide a minimum 
mounting space of 5 mm between the 
two juxtaposed relays as shown 
below.
Handling 
• The terminals are compatible with 
Faston receptacle #187 and are 
suitable for positive-lock mounting.
Use only Faston terminals with the 
specified numbers.
Select leads for connecting Faston 
receptacles with wire diameters that  
are within the allowable range for the 
load current. 
Do not apply excessive force to the 
terminals when mounting or 
dismounting the Faston receptacle. 
Also, do not insert terminals at an 
angle, or insert/remove multiple 
terminals at the same time. Be sure to 
insert and remove terminals carefully 
one at a time.
Refer to the following table for 
examples of positive-lock connectors 
made by AMP. Contact the 
manufacturer directly for details on 
connectors including availability. 
Note: The numbers shown in parentheses are for 
air-feeding.
Minimum Pulse Width of Double-
winding Latching Relays
• The minimum pulse width shown in 
the table of characteristics are values 
measured under conditions of ambient 
temperature at 23°C with rated 
operating voltage imposed on coil. The 
Relay may not provide a satisfactory 
performance as its holding ability 
decreases depending on the operating 
circuit conditions and ambient 
temperature, or decreases due to 
degradation over time.
In actual operation, impose to the coil 
a rated operating voltage with a pulse 
width that is suitable to the actual load, 
and reset the setting at least once a 
year, to correspond to the degradation 
over time.
• When using the Relay in a strong 
magnetic field environment, the 
magnetic body may be demagnetized 
due to the influence of environment, 
causing the Relay to malfunction.
Therefore, do not use the Relay in a 
strong magnetic field environment.
Degradation over Time of Double-
winding Latching Relays Holding 
Ability
• If a double-winding latching Relay is 
used left set for an extended period, 
changes over time will degrade the 
magnetic force, and the reduction in 
holding ability may cause the set 
status to be released.  This is also 
because of the properties of semi-
hard magnetic material, and the rate 
of degradation over time depends on 
the ambient environment (e.g., 
temperature, humidity, vibration, and 
presence or absence of external 
magnetic fields).Perform maintenance 
at least once a year by resetting, 
applying the rated voltage again, and 
then setting.
Wiring High Capacity (-E) Models
• High-capacity models (-E) have a 
structure that connects two terminals 
from one contact.
When designing the circuit, use both 
terminals.
If you use only one terminal, the relay 
may be unable to satisfy specified 
performance.
Correct Use
5 mm
min.
5 mm min.
Type
Receptacle 
terminals
Positive housing
#187
(Width 
4.75)
AMP170330-1
(170324-1)
AMP170331-1
(170325-1)
AMP170332-1
(170326-1)
AMP172074-1 
(natural color)
AMP172074-4 
(yellow)
AMP172074-5 
(green)
AMP172074-6 
(blue)
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. 
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad 
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious 
influence on lives  and property if used improperly. Make  sure that the ratings  and performance characteristics of the product provide a  margin of safety for the system or 
equipment, and be sure to provide the system or equipment with double safety mechanisms.